Kenwood TK-3360 Service Manual page 30

Hide thumbs Also See for TK-3360:
Table of Contents

Advertisement

TK-3360
Item
Condition
6. DTMF
1) TEST CH: 1
Deviation
Deviation meter fi lter
[Narrow]
LPF: 15kHz
HPF: OFF
PTT: ON
[Wide]
2) TEST CH: 1
PTT: ON
7. MSK
1) TEST CH: 1
Deviation
Deviation meter fi lter
[Narrow]
LPF: 15kHz
HPF: OFF
PTT: ON
[Wide]
2) TEST CH: 1
PTT: ON
8. Single Tone
1) TEST CH: 1
Deviation
Deviation meter fi lter
[Narrow]
LPF: 15kHz
HPF: OFF
PTT: ON
[Wide]
2) TEST CH: 1
PTT: ON
9. QT
1) TEST CH: Center, Low, High
Deviation
(3 points)
[Narrow]
Deviation meter fi lter
LPF: 3kHz
HPF: OFF
PTT: ON
[Wide]
2) TEST CH: 1
PTT: ON
10. DQT
1) TEST CH: 1
Deviation
Deviation meter fi lter
[Narrow]
LPF: 3kHz
HPF: OFF
PTT: ON
[Wide]
2) TEST CH: 1
PTT: ON
11. Battery
1) BATT terminal voltage: 5.9V
Warning
Level
30
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power
ANT
meter
SP/MIC
Deviation
connector
meter
Oscilloscope
AG
AF VTVM
DVM
TX-RX
BATT
terminal
Adjustment
Parts
Method
FPU
1.5kHz
±100Hz
3.0kHz
±100Hz
1.5kHz
±100Hz
3.0kHz
±100Hz
1.5kHz
±100Hz
3.0kHz
±100Hz
0.37kHz
±40Hz
0.75kHz
±40Hz
0.37kHz
±40Hz
0.75kHz
±40Hz
FPU
Write
BATT terminal voltage: 5.9V
Specifi cations / Remarks