Page 1
Compressor MODEL CPF4515 IMPORTANT Please make certain that the person who To learn more about Porter-Cable is to use this equipment carefully reads visit our website at: and understands these instructions before http://www.porter-cable.com starting operations. The Model and Serial No. plate is located on the main housing of the tool.
SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these symbols.
Page 3
IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire What Could Happen How To Prevent It It is normal for electrical contacts...
Page 4
HAZARD WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen How To Prevent It HAZARD WARNING: Risk from Flying Objects Always wear ANSI Z87.1 approved safety...
Page 5
HAZARD WARNING: Risk of Electrical Shock What Could Happen How To Prevent It Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, If it is not used Never operate compressor with properly it may cause electric shock.
Page 6
WARNING: Risk of Burns Never touch any exposed metal parts Touching exposed metal such as the on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns. hot for several minutes after operation. Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool.
Page 7
Unsafe operation of your air compressor Review and understand all instructions and warnings in this manual. could lead to serious injury or death to Become familiar with the operation and you or others. controls of the air compressor. Keep operating area clear of all persons, pets, and obstacles.
50%-75% average duty cycle be maintained; that is, the air compressor pump should not run more than 30-45 minutes in any given hour. SPECIFICATIONS Model No. CPF4515 Running Horsepower Bore 2.375 Stroke 1.35...
ASSEMBLY Assemble Handle To make installation easier, submerge handle grip into warm soapy water. Remove handle grip from soapy water Screw and slide onto handle. Insert the handle inside the compressor saddle and line up the two bolt holes on each side.
INSTALLATION HOW TO SET UP YOUR UNIT Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air. The air compressor pump and shroud are designed to allow for proper cooling.
Extension Cords Use extra air hose instead of an extension cord to avoid voltage drop and power loss to the motor, and to prevent overheating. If an extension cord must be used, be sure it is: • a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product •...
OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Description of Operation Become familiar with these controls before operating the unit.
Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet. Check Valve: When the air compressor is operating, the check valve is "open", allowing compressed air to Check Valve enter the air tank.
Move the On/Auto/Off lever to "On/Auto" position. The compressor will start. Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank. After 15 minutes, close the drain valve (clockwise). The air receiver will fill to "cut-out"...
MAINTENANCE Customer Responsibilities Daily Before or after each Yearly Frequently each Check Safety Valve ● Drain Tank ● ● 1 Air Filter Air compressor pump intake ● and exhaust valves 1- more frequent in dusty or humid conditions Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts.
Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture. After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored. NOTE: If drain valve is plugged, release all air pressure.
To Replace or Clean Check Valve Release all air pressure from air tank. See "To Drain Tank" in the "Maintenance" section. Unplug outfit. Outlet Tube Remove shrouds. Using an adjustable wrench loosen outlet tube nut at air tank and pump. Carefully move outlet tube away from check valve.
To Replace Regulator Release all air pressure from air tank. See "To Drain Tank" in the "Maintenance" section. Unplug outfit. Using an adjustable wrench remove the outlet pressure gauge and quick connect from the regulator. Remove the regulator. Apply pipe sealant tape to the nipple on the standpipe.
Page 19
STORAGE Before you store the air compressor, make sure you do the following: Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary. Set the On/Auto/Off lever to "Off". Turn the regulator counterclockwise and set the outlet pressure to zero. Remove the air tool or accessory.
TROUBLESHOOTING Risk of Unsafe Operation. Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.
Page 21
PROBLEM CAUSE CORRECTION Pressure reading It is normal for "some" If there is an excessive on the regulated pressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the used.
Page 22
PROBLEM CAUSE CORRECTION Regulator will Damaged regulator. Replace. not shut off air outlet. Motor will not Motor overload protection Let motor cool off and run. overload switch will switch has tripped. automatically reset. Tank pressure exceeds Motor will start automatically when tank pressure drops pressure switch "cut-in"...
• Use reasonable care in the operation and maintenance of the product as described in the Owners Manual(s). • Deliver or ship the product to the nearest Porter-Cable Authorized Warranty Service Center. Freight costs, if any, must be paid by the purchaser.