8. SERVICE PROCEDURE

MICRO-COMPUTER

To check the microcomputer firmware version, press 6.1 CH IN button and SLEEP button simultaneously while
power is on. The version number is shown on the main display of the unit.
Ex. V 020716 01
TUNER
1. Requried Equipments
- AM Standard Signal Generator (AM SSG)
- Oscilloscope
- AC Voltmeter
- FM Standard Signal Generator (FM SSG)
- Stereo Modulator
Note : Disconnect external FM antenna prior to alignment.

2. Alignment

2-1. Alignment Test Points
- Audio Generator
- Distortion Meter
- DC Voltmeter
- Frequency Counter
59

2-2. AM(MW) Alignment

Output of signal generator should not be greater than necessary to obtain an optimum output reading.
Signal generator modulation ................................................................. 30%
Signal frequency ................................................................................ 400Hz
Modulation frequency ........................................... 603, 999, 1404kHz (/A/K/N)
Modulation frequency ............................................ 600, 1000, 1400kHz (/U)
Switch ........................................................... press the BAND Button to AM
Signal
Set
generator
frequency
Step
Subject
setting
setting
1
Tunning
522kHz
522kHz
voltage
(/A/K/N)
(/A/K/N)
520kHz
520kHz
(/U)
(/U)
2
IF Tracking
603kHz
603kHz
(/A/K/N)
(/A/K/N)
600kHz
600kHz
(/U)
(/U)
3
RF Tracking
603kHz
603kHz
(/A/K/N)
(/A/K/N)
600kHz
600kHz
(/U)
(/U)
4
Seek level
999kHz
999kHz
(/A/K/N)
(/A/K/N)
1000kHz
1000kHz
(/U)
(/U)
2-3. LW Alignment (/A/N)
Output of signal generator should not be greater than necessary to obtain an optimum output reading.
Signal generator modulation ................................................................. 30%
Signal frequency ................................................................................ 400Hz
Modulation frequency ....................................................... 162, 207, 252kHz
Switch ........................................................... press the BAND Button to LW
Signal
Set
generator
frequency
Step
Subject
setting
setting
1
Tunning
152kHz
152kHz
voltage
2
RF Tracking
162kHz
162kHz
3
Seek level
207kHz
207kHz
Equipment
Adjustment
Adjust for
connection
point
DC voltmeter
RF BLOCK
522 kHz : 1.0 ~ 1.3V
OSC coil
1611 kHz : 7.0 ~ 8.5V
AC voltmeter
IF BLOCK
Maximize audio output
oscilloscope
Coil
tape monitor
KSNT-111I
L/R
AC voltmeter
RF BLOCK
Maximize audio output
oscilloscope
ANT coil
Repeat LOW, HIGH
tape monitor
frequency
L/R
AC voltmeter
SVR 03
Tuned on point
oscilloscope
tape monitor
L/R
Equipment
Adjustment
Adjust for
connection
point
DC voltmeter
RF BLOCK
522 kHz : 1.5 ~ 2.3V
OSC coil
1611 kHz : 6.0 ~ 7.5V
AC voltmeter
RF BLOCK
Maximize audio output
oscilloscope
ANT coil
Repeat LOW, HIGH
tape monitor
frequency
L/R
AC voltmeter
Tuned on point
oscilloscope
tape monitor
L/R