Dynamix RC 903-V35FE1 User Manual page 19

V.35 to fractional e1 interface converter
Table of Contents

Advertisement

When using "Master Clock — Slave Clock" connection structure, if DXC and MUX
devices are connected in series in E1 link, then DXC, MUX and remote converter should
be at Slave Clock Mode (following E1 link clock).
2)
Point-to-point fractional E1 mode in "Terminal clock — Slave clock"
structure
(Terminal clock)
(Clock source)
When remote DTE equipment has to follow the clock phase of local DTE equipment,
which is to say, TX CLOCK of local DTE is internal clock source, users can set Terminal
Clock Mode in local converter, and Slave Clock Mode in remote converter, and must
configure clock frequency at V.35 interface of local DTE equipment.
When using "Terminal clock — Slave clock" connection structure, if DXC and MUX
devices are connected in series in E1 link, then DXC, MUX and remote converter should
be at Slave Clock Mode (following E1 link clock).
3)
Point-to-point fractional E1 mode in "Slave clock — Slave clock" structure
(Slave clock)
When using Slave Clock Mode at both sides, it is required to ensure that the clock source
is provided by DXC, MUX or other PCM fractional E1 equipment in the E1 link, and there
is only one clock source in the E1 link.
4) Extended connection type
In this connection type, the converter is not used in pairs, but connected with equipment of
(Slave clock)
(Clock source)
(Slave clock)
18