5.5.4

Setting the starting points and the operating programs

(see chapter 5.5.3)
--.-- 45%rH HA0
--.-- 45%rH HA0
--.-- 45%rH HA0
(see chapter 5.5.2)
First select the desired day of the week or the starting point, respectively (Monday 1, Monday 2 .....
Sunday 1, Sunday 2), then define the operation settings which should become active at the starting
point.
Available settings:
Factory setting:
Notes on setting:
Monday 1
Monday 2
Sunday 2
Hours (Format: hh)
Minutes (Format: mm)
Reference humidity value in %rH
Operating mode ("H": for humidification, "P": for purification (without humidi-
fication) and "C": for combined mode (purification and humidification))
Fan step (0, 1, 2, 3, 4)
"– –:– – 45%rH HA0"
After calling the modification mode set the hour, the minute, the reference
humidity value, the operating mode and the fan step for the selected starting
point. Confirm each setting with the <Enter> key.
To deactivate a starting point (display: – – : – –) press both arrow keys simul-
taneously when the hour field flashes. Confirm with the <Enter> key. Repeat
this procedure with the minute field.
The switch off the unit at a certain time select fan step "0".
modify
confirm
Monday 1
New Value
cancel
Monday 1
Old Value
Monday 1
--.-- 45%rH HA0
see notes on setting