The Defensor PH15/PH15A can be operated in the following operating modes:
– Operation as air humidifier
In the humidifier mode the ventilator and the centrifuge are running only, if the actual humidity
value is below the set reference value.
Note: if the actual humidity value remains below the reference value for a prolonged period of
time, the fan must be switched to the next highest level.
– Operation as air purifier with humidification
In this operating mode the fan is running continuously. The centrifuge is only switched on if the
actual humidity value is below the set reference value.
– Operation as air purifier without humidification
In this operating mode the fan is running continuously. The centrifuge remains switched off.
3.6

Options

Silver ionisation
Assembly kit to equip the unit with silver ionisation electrodes
to degerminate the water in the base tub with silver ions.
Note: The silver ionisation kit must be installed and config-
ured only by a service technician of your Defensor
sentative.
Radio humidity sensor
The
radio humidity
grated
humidity sensor. The maximum range of the radio
humidity sensor
Note: the
radio humidity sensor
must be installed and configured only by a service technician
of your Defensor
Leakage sensor
Assembly kit to equip the
leakage sensor. If the leakage sensor detects a leakage,
the inlet valve (PH15A only) is closed and error message
is triggered.
Note: The leakage sensor must be installed and configured
only by a service technician of your Defensor
tive.
sensor can be used instead of the inte-
in an open room is 25 m
as well as the receiver board
representative.
Defensor
PH15/PH15A with a
Defensor
PH15
repre-
representa-
11
Defensor
PH15A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ph15a

Table of Contents