JVC PD-Z50DX4/S Service Manual page 31

Pdp colour television
Table of Contents

Advertisement

< Page 2 of screen (DISPLAY UNIT) >
Detection item
name
Fan lock
FAN
Abnormal of operation of
ALM
PDP (PANEL)
Abnormal rise of
TMP
temperature in PDP
(PANEL)
Abnormal rise of
ATP
temperature in AUDIO
PWB
Short circuit detection of
ASH
AUDIO PWB
Panel communication
PNL
Panel memory
MEM
Temp. sensor
TMP
operation
Audio control
AIO
5.1.7 METHOD OF DISPLAY WHEN A RASTER IS NOT OUTPUT
In the state where a raster is not output by breakdown of the set, an error is displayed by blink of the POWER LED.
TYPE of error
Low bias line short protection
Abnormal of operation of PDP (PANEL)
Abnormal rise of temperature in PDP (PANEL)
< Explanation of operation >
If error is detected, the power is turned off.
Shortly after a power is turned off, POWER LED will be blinked.
Power cannot be turned on until the power cord takes out and inserts, after a power is turned off.
Item
Detection content
Confirm the operation of the cooling fan.
IC807 [DISPLAY INTERFACE PWB]
Confirm the operation of the panel
protection.
[PDP UNIT]
It detects whether the temperature in a
display unit is normal.
IC8101 [TEMP. SENSOR PWB]
Not used.
Not used.
It confirm whether panel communication
is normal.
[PDP UNIT]
Confirmation of reply of ACK signal
2
which uses I
C communication.
IC805 [INTERFACE PWB]
Same as above.
IC8101 [TEMP. SENSOR PWB]
Same as above.
IC6521 [AUDIO PWB]
Item name
LOB
ALM
TMP
Diagnosis
signal (line)
FAN_LOCK
SDA
SDA
---
---
SDA
SDA
SDA
SDA
POWER LED flash cycle
Low luminance blue Flash 1.0 second / Low luminance blue Out 1.0 seconds
High luminance blue Flash 1.0 second / High luminance blue Out 1.0 seconds
High luminance blue Flash 2.0 second / High luminance blue Out 2.0 seconds
Detection timing
Detection starts 8 seconds after the
power is turned on.
Detection is performed every 16ms.
If errors continues between 300ms, the
power is turned off.
Detection starts 8 seconds after the
power is turned on.
Detection is performed every 16ms.
If errors continues between 300ms, the
power is turned off.
Detection starts 8 seconds after the
power is turned on.
Detection is performed every 0.5 seconds.
If a temperature rises beyond the
temperature of 71°C for detection of
error over the predetermined 120 times,
the power is turned off.
---
---
2
If it checks whenever I
C communication
is performed, and no reply of ACK
signal, an error will be counted.
2
If it checks whenever I
C communication
is performed, and no reply of ACK
signal, an error will be counted.
Same as above.
Same as above.
(No.YA229)1-31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pd-z50dx4

Table of Contents