JVC PD-Z50DX4/S Service Manual page 30

Pdp colour television
Table of Contents

Advertisement

5.1.6 DETAILS
Self check is performed for the following items:
< Page 1 of screen (RECEIVER UNIT) >
Detection item
Display
Low bias line short
protection
Fan lock
Presence of sync signal
SYNC Confirmation of presence of video
AC power input
Main CPU
MSM
communication
Digital tuner
Main memory
MEM
AV select switch
AVSW Same as above.
3 dimensions YC
separator
Multi sound process
RF tuner
Ghost reduction
DIST process
RGB process
DVI (Digital communication)
Digital input
HDMI
1-30 (No.YA229)
Detection content
LOB
Confirmation of operation of the low bais
(2.5V / 3.3V / 5V / 9V) protection circuit.
Q9822 [REGULATOR PWB]
FAN
Not used.
sync signal.
M : Main sync signal
S : Sub sync signal
HD : Component sync signal
IC201 [ANALOG SIGNAL PWB]
TIM
Not used.
Confirmation of ACK (response)
signal which uses sync communications
with Chassis CPU.
IC7501 [DIGITAL SIGNAL PWB]
DIGI
Not used.
Confirmation of reply of ACK signal
2
which uses I
C communication.
IC7602 [DIGITAL SIGNAL PWB]
IC301, IC501 [ANALOG SIGNAL PWB]
YC
Same as above.
IC1001 [DIGITAL SIGNAL PWB]
AIO
Same as above.
IC3501 [RECEIVER PWB]
TUN
Confirmation of reply of ACK signal
2
which uses I
C communication.
TU3001 [RECEIVER PWB]
GCR
Not used.
IP
Confirmation of reply of ACK signal
2
which uses I
C communication.
IC3001 [DIGITAL SIGNAL PWB]
RGB
Confirmation of reply of ACK signal
2
which uses I
C communication.
IC4001 [DIGITAL SIGNAL PWB]
DVI
Same as above.
IC6101 [DIGITAL SIGNAL PWB]
Confirmation of reply of ACK signal
2
which uses I
C communication.
IC8001 [DIGITAL SIGNAL PWB]
Diagnosis
Detection timing
signal (line)
LB_PRO
Detection starts 3 seconds after the
power is turned on.
If error continues between 400ms the
power is turned off.
---
SDA
Confirmation of presence of sync signal
in video signal.
---
WAKE
If it checks whenever sync communication
with Chassis CPUperformed and no reply
of ACK signal an error will be counted.
---
SDA
If it checks whenever I
is performed and no reply of ACK signal
an error will be counted.
SDA
Same as above.
SDA
Same as above.
SDA
Same as above.
SDA
If it checks whenever I
is performed and no reply of ACK signal
an error will be counted.
---
SDA
If it checks whenever I
is performed and no reply of ACK signal
an error will be counted.
SDA
If it checks whenever I
is performed and no reply of ACK signal
an error will be counted.
SDA
Same as above.
SDA
Same as above.
---
---
---
2
C communication
2
C communication
---
2
C communication
2
C communication

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pd-z50dx4

Table of Contents