Section 9
Disassembly
Remove Ignition Modules
1. Disconnect the lead(s)* from each ignition
module. See Figure 9-46. *Modules for non-
SMART-SPARK
ignition systems have only one
™
kill lead.
Figure 9-46. Disconnecting Leads from Ignition
Modules.
2. Rotate the flywheel so the magnet is away from
the modules.
3. Remove the mounting screws and ignition
modules. Note the position of ignition modules.
Figure 9-47. Position of SMART-SPARK
Module.
Remove Intake Manifold
1. Remove the four hex flange screws securing the
intake manifold to the cylinder heads. Note
which screws hold the wiring clamps.
2. Remove the intake manifold and the intake
manifold gaskets (aluminum intake manifolds) or
O-Rings (plastic intake manifolds). See Figure
9-48.
9.12
3. Leave the wiring harness attached to the
manifold.
Aluminum
Intake
Manifold
Plastic Intake
Manifold
Two-Barrel
Intake Manifold
Ignition
™
Figure 9-48. Removing Intake Manifold.