Kohler CH18-CH26 Service Manual page 185

Horizontal crankshaft
Hide thumbs Also See for CH18-CH26:
Table of Contents

Advertisement

Figure 9-33. Removing the Spark Advance Module
(Applicable Models).
4. Remove the three (each side) hex flange screws
securing the outer baffles. Note the location of
any lifting strap and position of the two short
screws (one each side on bottom) for reassembly.
See Figure 9-34.
Figure 9-34. Note Location of Two Short Screws.
Figure 9-35. Removing Outer Baffles.
5. Remove the outer baffles on both sides. See
Figure 9-35.
6. On engines equipped with a metal grass screen,
remove the screen before removing the blower
housing. See Figure 9-36. Plastic grass screens
can be removed after the blower housing is
removed.
Figure 9-36. Removing Metal Grass Screen.
7. Remove the lower blower housing screw and
washer securing the rectifier-regulator ground
lead or grounding strap.
8. Two-Barrel Carburetor Models Only: Remove
the two screws securing the debris shield to the
blower housing. The wiring harness is attached
to the underside of shield. See Figure 9-37.