11 - M
It is necessary to thoroughly clean the conditioner's internal elements every year.
- Unplug the appliance.
- Place the appliance on the ground to disassemble it (4 screws).
- Vacuum the 4 air entry and exit grids.
- Remove the upper cover (2 screws) (1).
- Snap o from the top the 2 columns in order to access the 8 screws of the 2 front sections (2).
- Disassemble the front sections by removing the screws (square end pieces, not supplied).
- Thoroughly clean the ribs of the 2 exchangers with a vacuum cleaner (3).
- Repeat these instructions in the opposite order to reassemble the appliance.
(1)
12 - O
If the conditioner is not working, there may be loss of synchronism between the appliance and the remote control.
Synchronising procedure:
- Remove the conditioner housing upper cover (4 screws) (1).
- To turn on the remote control, press and hold down the
- Place the switch, located under the conditioner, in position 1.The green LED on the board comes on (2).
- Press and hold down the On/O button (brown button) on the board for more than 6 seconds, then release (3). The green LED will then start to ash
(synchronising mode).
(1)
- Simultaneously press the
and
- As soon as the green LED on the board stops ashing (end of synchronising mode), the conditioner and remote control are then synchronised.
- Exit "RF" mode by pressing the
AINTENANCE
(2)
PERATING FAULTS
key for about 8 seconds, until the
(2)
keys on the remote control until ! is displayed
key on the remote control.
(3)
indicator goes o .
(3)
Green LED
.
Ribs of the
2 exchangers
On/ o button