Work Right

lOOk aT THE layOuT (refer to the fishbone Method below)
• Find the most easily located power point. This is your starting location at the fish's head.
Your turnaround is the 'tail'.
• Check the room layout (position of desks, tables, chairs, fittings etc.)
• Check the condition of the floor - how dirty it is on a scale of 1 to 10.
Plan THE PROCESS
• See in your mind the fishbone method over the entire area or room to be cleaned.
• Decide which areas are to be detail cleaned (the spine), or spot cleaned (the ribs).
ClEan SMaRTER
• Work away from the power point.
• Work one side of the fishbone towards tail. Then back the other side towards head.
• Work to the plan - long strokes for the detail clean area and short dabs for the spot cleans.
1
fishhead Start
Spine Heavy Traffic Areas - Detail Clean
2
Ribs Light Traffic - Spot Clean
3
6
Operate Right
How to vacuum easier and faster with no back strain.
1. Stand upright, with the bent hand piece section parallel to the floor.
2. Hold the bent hand piece with one hand at a comfortable arm's length. Use your free hand to hold the
hose to help guide the vacuum as you work.
3. Move forward and away from the power point.
4. Use easy underarm swinging motion when detail cleaning and short dabs when spot cleaning, always
standing upright.
5. Once the end of the power cord has been reached and work completed, return to the power point along
the cord line and disconnect the power cord from the power point.
6. If work is not completed move to the next area, connect power cord to the nearest power point and
repeat steps 1 through 6.
7. If work is completed disconnect power cord from power point then wind from the canister towards
the end of the power cord to reduce likelihood of cable twists. In the process check for nicks, cuts,
fractures, and knots.

Troubleshooting

WaRnInG: TO REDuCE RISk Of PERSOnal InJuRy, unPluG CanISTER BEfORE
aTTEMPTInG TO SOlVE PROBlEM OR WHEn SERVICInG
PROBlEM:
CauSE:
Power cord not firmly plugged
Vacuum cleaner
not working
into power point.
Vacuum cleaner not turned on.
Thermal protector shuts off
vacuum cleaner due to high
motor temperature.
Circuit breaker or RCD has tripped. Reset Circuit breaker or RCD.
Dust bag full.
Vacuum cleaner
has no/poor
Dust bag not installed
suction
correctly.
Hose not installed correctly.
Blockages.
Filters blocked.

Service Requirements

Our products are designed and built to be functional and durable. As a result, if you maintain your vacuum
cleaner as instructed, it is unlikely to require servicing. For information on use and maintenance please read
the Product and Training Manual thoroughly. Should you require servicing we recommend our Pacvac Gold
Level Service Centres. For your nearest centre visit www.pacvac.com, alternatively contact Pacvac on
08 9479 1444 or e-mail sales@pacvac.com.
SOluTIOn:
Plug power cord into power point firmly.
Press on/off button.
Turn main switch off and unplug the vacuum cleaner.
Conduct safety and maintenance checks found in the
Product and Training Manual. After 30 minutes the
vacuum cleaner should be ready for use. If not contact
Pacvac for your nearest Authorised Pacvac Service Agent.
Remove, empty and clean dust bag.
Remove and empty dust bag making sure the rubber
seal is fitted correctly.
Reconnect hose and ensure correctly sealed.
Remove hose, wand and floor tools; remove any blockages.
Clean filters.
www.pacvac.com
Support: 08 9479 1444