System And Component Diagnostics - Proheat M50 G-II PCM Service Manual

M series
Hide thumbs Also See for M50 G-II PCM:
Table of Contents

Advertisement

4-2
4.1 SYSTEM AND COMPONENT
DIAGNOSTICS
The G-II PCM continually monitors the PROHEAT operating conditions. If the G-II
PCM detects a problem, the indicator light flashes a diagnostic code(s) on
the G-II PCM status LED.
The diagnostic indicator light may also be located:
• In the toggle of the ON/OFF Switch provided by PROHEAT (standard
installation kit).
• In the PROHEAT Timer manual ON light (red).
• In an OEM indicator light package.
• In the remote switch (PROHEAT P/N PK0091) used for troubleshooting.
G-II PCM STATIUS
LIGHT COLOUR
GREEN
GREEN
GREEN
GREEN
RED
RED
Flashing alternating
RED then GREEN
ORANGE
It is possible to have one or more diagnostic codes displayed. Codes are displayed
by a series of short flashes (that corresponds to the number of the Diagnostic
code) then turned off for 2 seconds and then the next code is displayed.
Note: The Same code is displayed only if one diagnostic code is active.
For example if a 7 and 10 Diagnostic Code occurs together, the G-II PCM status
light will flash Red 7 times then pause for 2 seconds then flash Red 10 times.
Similarly the remote ON/OFF Switch, Timer red manual light (T-II Timer will also
display the code on LCD) or OEM indicator light (installation options) will flash 7
times, pause and then 10 times.
STATE
Flash Twice
Power Up.When power is first applied
(fast) then off
to the G-II PCM the Green LED will
flash (fast) twice to indicate that the
G-II PCM has booted up.
On Solid
Heater is switched on Via analog
switch inputs and is operating
normally
Off then two
Heater is connected to CANBus
flashes then
network and is communicating on the
off again
network but is not switched on
On Solid with
Heater is switched on Via Analog or
two flashes then
CANBus switch inputs and is operating
on solid again
normally and communicating on the
network
On Solid
Software problem detected. Contact
Proheat for further information.
Flashing
Diagnostic Blink Code(s)
Flashing
Data Link cable incorrectly installed.
Remove the data cable and power
from G-II PCM for 20 seconds. Then
re-apply power first, and then connect
the data cable.
On Solid for up
Motor is locked up or frozen
to 60 seconds
PROHEAT M-SERIES G-II PCM SERVICE MANUAL