Motor
• Rotate motor shaft until motor drops into fuel pump gear.
• Ensure correct alignment (refer to 'Motor Replacement' on page 4-33)
• Torque bolts (4) to 75 in. lbs. ± 7 in. lbs. (8.5 Nm ± 0.8 Nm).
Blower Housing
• Torque bolts (2) to 75 in. lbs. ± 7 in. lbs. (8.5 Nm ± 0.8 Nm).

Ignition Module

• Torque screws (2) to 75 in. lbs. ± 7 in. lbs. (8.5 Nm ± 0.8 Nm).
Dual Mode Temperature Sensor
• Install O-ring onto sensor.
• Torque sensor to 100 in. lbs. ± 10 in. lbs. (11.6 Nm ± 1.1 Nm).
Burner Head/Heat Exchanger
• Torque bolts (2) to 100 in. lbs. ± 10 in. lbs. (11.6 Nm ± 1.1 Nm).
1-10