INSTALLATION
Continued
Propane/LP Gas Conversion
To convert to propane/LP gas, the burner inlet fitting and pilot orifice
must be replaced and the regulator pressure must be reset. The
propane/LP burner inlet fitting is supplied with the orifice installed.
The propane/LP pilot orifice for converting the pilot is supplied and
is marked with a red stripe.
1.
Remove control rod extension and piezo ignitor by pulling gently.
2.
Remove screws that attach pilot assembly to valve cover and
valve cover to burner pan (see Figure 7).
3.
Remove valve cover.
4.
Using a wrench, remove gas control valve by turning counter-
clockwise (see Figure 8).
5.
Remove the burner inlet fitting from the gas control assembly
(see Figure 8). DO NOT remove the orifice from this fitting.
The propane/LP burner inlet fitting is included in the hardware
kit (see Figure 9).
6.
Be sure to use the correct orifice for your appliance. The orifice
kit included with this appliance contains an orifice installed in
an air mixer fitting.
7.
Using thread sealant (resistant to the action of propane/LP gas) on
smaller end of fitting, screw the burner inlet fitting into the outlet
side of the gas control (see Figure 8). Tighten using a wrench.
Control
Knob
Control Rod
Extension
Figure 7 - Removing/Installing Cover, Control Knob, and Piezo
Ignitor
Burner Pan
Assembly
Burner Inlet Fitting
Figure 8 - Removing/Installing Gas Control Valve
109220-01C
Thermocouple
Screw
Valve Cover
Ignitor
Piezo Ignitor
Burner Inlet
Fitting for
Natural Gas
Gas Control
Valve
Control Rod
8. Thread gas control valve and burner inlet fitting into burner
manifold (see Figure 8). Use thread sealant on male threads of
burner inlet fitting. Secure with a wrench. Make sure control
rod is facing the front (see Figure 8).
9. To adjust regulator pressure, remove the brass hex plug from
regulator (see Figure 10).
10. Remove the plastic pressure button from the brass plug (see
Figure 10).
11. Reverse the plastic pressure button and replace it into the brass
plug (see Figure 10).
12. Replace brass plug into regulator.
13. Using two screws removed in step 2, replace valve cover.
14. Gently loosen and remove the pilot line connection from the
pilot bracket (see Figure 11).
15. Replace injector with propane/LP injector with red stripe.
16. Replace and tighten pilot line to bracket.
17. Using screws removed in step 2, reattach pilot bracket to
valve cover.
18. Continue with step 1 under Hearth Pan Installation, page 6.
Injector for
Natural Gas
NATURAL
GAS FITTING
Figure 9 - Burner Inlet Fittings with Injectors
Pilot
Plastic Pressure
Button Positioned
for Natural Gas
Figure 10 - Adjusting Regulator Pressure for Conversion
Pilot Bracket
Pilot Injector
Figure 11 - Installing Propane/LP Pilot Orifice
INSTALLATION
Hearth Pan Installation (Cont.)
Injector for
Propane/LP
Gas
PROPANE/LP
GAS FITTING
Regulator
Reversed Plastic
Pressure Button
for Propane/LP
Conversion
Pilot Adjustment Screw