The fireplace chimney flue and vent must be drafting properly. To
check the vent for proper drafting: Light a tightly rolled newspaper
on one end and place it at the inside front edge of the fireplace.
Observe the smoke and be sure the vent is properly drawing it up
the chimney. If the smoke spills out into the room, extinguish the
flame and remove any obstruction until proper venting is achieved.
The chimney flue damper must be fixed open to provide a minimum
of 81 sq. in. of free air opening during operation of this log set. A multi-
purpose damper clamp is provided to fix the damper in position.
INSTALLING DAMPER CLAMP
Secure the damper stop clamp provided to the leading edge of the
damper as shown in Figure 3. If for any reason this clamp doesn't
work on your fireplace, another suitable clamp or permanent stop
must be installed, or the damper blade must be cut or removed.
Damper
Masonry Fireplace
Damper
Clamp
Figure 3 - Attaching Damper Clamp
109220-01C
Damper
Clamp
Damper
Manufactured Fireplace
Damper
Venting Specifications for Installation
Installing Damper Clamp

Connecting to Gas Supply

CONNECTING TO GAS SUPPLY
WARNING: A qualified service person must con-
nect log set to gas supply. Follow all local codes.
Installation Items Needed
Before installing log set, make sure you have the items listed below.
• piping (check local codes)
• sealant (resistant to LP gas)
• equipment shutoff valve
• test gauge connection
• adjustable (crescent) wrench or pliers
• sediment trap
• tee joint
• pipe wrench
CAUTION: Use only new, black iron or steel pipe.
Internally-tinned copper tubing may be used in certain
areas. Check your local codes. Use pipe of 1/2" diam-
eter or greater to allow proper gas volume to log set. If
pipe is too small, undue loss of volume will occur.
Installation must include an equipment shutoff valve, union, and
plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from log set (see Figure 4).
IMPORTANT: Install equipment shutoff valve in an accessible
location. The equipment shutoff valve is for turning on or shutting
off the gas to the appliance.
Approved Flexible Gas Hose (no longer
than 36" if required by local codes)
CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap*
3" Minimum
Cap
Figure 4 - Gas Connection
* Purchase the optional CSA design-certified equipment shutoff
valve from your dealer.
** Minimum inlet pressure for purpose of input adjustment.
INSTALLATION
From Gas Meter
(5" W.C.** to
10.5" W.C.
Pressure)
Pipe Nipple
Tee Joint
Sediment Trap
5 5