Inspecting Burners; Cleaning And Maintenance; Pilot Assembly - Barbeques Galore BVDA18M Owner's Manual

Natural gas log vented decorative appliance convertible from natural gas to propane/lp gas
Table of Contents

Advertisement

OPERATING APPLIANCE
10
To Turn Off Gas to Appliance

INSPECTING BURNERS

Pilot Assembly

Burner Flame Pattern

CLEANING AND MAINTENANCE

OPERATING APPLIANCE
Continued
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Appliance
1.
Turn control knob clockwise
2. Press in and turn control clockwise
position.
Shutting Off Burner Only (pilot stays lit)
Turn control knob clockwise
INSPECTING BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the proper flame height.
Alterations may have occurred during shipping and handling. The
pilot is located on the back right hand side of the burner.
The thermocouple should be fully enveloped in the flame. The flame
should not be lifting off of the thermocouple element.
If your pilot assembly does not meet these requirements:
• Access the pilot adjustment screw through slot in valve cover.
Turn adjustment screw clockwise to decrease or counterclock-
wise to increase the flame to proper size (see Figure 11, page 7).
Do not remove the adjustment screw.
• see Troubleshooting, pages 11 through 13
Pilot
Figure 17 - Correct Pilot Flame Pattern
to the PILOT position.
to the OFF
to the PILOT position.
Thermocouple
BURNER FLAME PATTERN
Burner flames will be steady; not lifting or floating. Flames should
go up through the middle of logset. Flames should not "spill" to the
edges of the pan or sides of the logset.
Figure 18 shows a typical flame pattern. If burner flame pattern differs
from that described:
• turn appliance off (see To Turn Off Gas to Appliance)
• see Troubleshooting, pages 11 through 13
Figure 18 - Typical Flame Pattern
CLEANING AND MAINTENANCE
• Keep the area around the log set clean and clear of debris.
• Occasionally, you may use a soft bristle brush to clean logs.
• Periodically inspect air mixer and burner tube for foreign matter
blocking air inlet and flame holes.
• Once every year a qualified agency or certified chimney sweep
should examine and clean the venting system of the fireplace.