INSTALLATION

4
Flue Opening Specifications

Check Gas Type

INSTALLATION
WARNING: The Massachusetts State Board re-
quires all installations be performed by a Licensed
Plumber or Gas Fitter. Massachusetts state code re-
quires all vent dampers be welded open or removed.
CAUTION: Do not remove the data plates at-
tached to the burner pan. The data plates contain
important warranty information.
WARNING: Before installing in a solid fuel burn-
ing fireplace, the chimney flue and firebox must be
cleaned of soot, creosote, ashes and loose paint by
a qualified chimney cleaner. Creosote will ignite if
highly heated. A dirty chimney flue may create and
distribute soot within the house. Inspect chimney
flue for damage.
NOTICE: Installation, service, and repair of this appli-
ance must be performed by a qualified installer, ser-
vice agency, company or gas supplier experienced
with this type of gas appliance. Only factory autho-
rized components listed in these instructions may be
used in accordance with the manufacturer's instruc-
tions and all codes and requirements of the authority
having jurisdiction. Any modifications to this kit, or
use of unauthorized components or accessory items
will void the manufacturer's warranty, and may result
in a hazardous condition.
FLUE OPENING SPECIFICATIONS
Note: This vented appliance must be installed only in a solid-fuel
burning fireplace with a working flue and constructed of noncom-
bustible material.
The charts in Figure 2 indicate technical information regarding the
installation of your gas log set. Please make sure that all of the
specifications shown are applicable before installation is attempted.
The fireplace must include a working flue and venting system with
the minimum openings shown in the Figure 2. The minimum flue
sizes shown in Figure 2 are based on a 6' chimney height using round
pipe. Your minimum flue size will vary based on input rate and
chimney height. Refer to the National Fuel Gas Code ANSI Z233.1/
NFPA 54, Section 6.6, for details
Btu Input
MODEL
DESCRIPTION
BVDA18M 18" Dual Burner 55,000 45,000 .116 32 .082 45
BVDA24M 24" Dual Burner 65,000 55,000 .138 29 .086 44
BVDA30M 30" Dual Burner 70,000 60,000 .1405 28 .089 43
MINIMUM FIREBOX SIZES
LOG FRONT
BACK
SIZE
WIDTH WIDTH* DEPTH HEIGHT FLUE SIZE
18"
34"
16"
3
24"
35
/
"
17"
4
30"
42"
27"
*At depth indicated
SPECIFICATIONS (W.C.)
FUEL INLET PRESSURE
Min.
Max.
NG
7
10.5
LP
11
14
Figure 2 - Technical Information Charts
CHECK GAS TYPE
Use only natural gas. If your gas supply is not natural gas, you must
convert the appliance to Propane/LP. Follow the instructions on
page 7.
If the fireplace does not have a gas supply shut-off valve, one must
be installed.
Burner Orifice
Btu Input
Natural
Natural
Propane/
Gas
In. Num. In. Num.
LP Gas
MINIMUM
14"
18"
8" diam.
1
15
/
"
18"
8" diam.
2
18"
18"
9" diam.
MANIFOLD PRESSURE
6
10
Propane/LP
109220-01C