Unit protection devices
Introduction

Check List

The following check list has been prepared to assist you in
understanding the differences from other types of heating
systems you may have installed and help to understand and
comply with all of the technical details contained within this
document to ensure a successful installation.
System cleaning and Water Characteristics
In the case of a new installation, or cleaning the circuit, it is
necessary to perform a preventive cleaning of the
system. In order to guarantee the good operation of the
product,each time you clean the system, replace the water
or add glycol, check that the liquid appears clear, without
visibleimpurities and that the hardness is less than 20°f.
system contamination; the system filter should be fitted
internally on the return pipe.
Recommended system cleansers and inhibitors are listed
below.
Sentinel
All external connecting pipe work should be suitably
insulated using Armaflex flex or similar
Installation Pack
The following items are required for the installation of the Aeromax Plus Air Source Heat Pump
Product Code
Description
KHP0029
4kW, 6kW & 8kW Installation Pack
KHP0030
12kW Installation Pack
KHP0026
15kW Installation Pack
Pack Contents
1 x System filter
2 x 750mm flexible hoses
including 90° elbow,
pre-insulated
Diagnostic indicator
System Antifreeze / Inhibitor - Clear
Product Code
Description
KHP0023
1 x 25 litre system antifreeze inhibitor - Clear
Radiator System Circuit
conventional boiler the radiators should have been
designed to suit the lower mean temperature.
the parameters on the heat pump are optimised for use
on radiator systems.
Retrofit Situations
contaminates in the water circuit. The existing radiator
circuit must be chemically cleaned and thoroughly flushed
before installation when fitting in a retrofit situation.
NOTE
NOTE
W Plan diverter valve
(heat pump specific)
Programable room stat
7 day hot water
programmer
back up or clients wishing to alter the operating
parameters of the unit; we recommend the
purchase of our advanced controller. See
manual product code KHP0008
It is the installer's responsibility to ensure
correct sizing and provision of both the
domestic circulating pump & any associated
central heating expansion vessel
Anti vibration pads
Anti vibration pads
valve with lever arm
1 x 25 litre clear - system
antifreeze inhibitor