7 day hot water programmer

Installation

on the bottom edge of the unit.
be clearances of at least 140 mm to the right, 15mm to the
left, 30mm above and 100mm below in order to mount
the plug-on module.
the wall using suitable wood screws or to a fl ush mounted
1-gang electrical accessory box using M3.5 screws.
cabling, or from below for surface cabling. If surface cable
is used, cut out cable access slot on plug-on module prior
to mounting the module.
Wiring - See page 19 for further details

Please Note:

Always switch off mains fi rst and never fi t programmer to a live wallplate.

DIL Switch Settings

Before mounting the unit, ensure the 4 DIL switches on the
rear have been moved to the required settings.
Tick the INSTALLER SETTING box on the inside fl ap label
to notify user in which mode their unit is set (24hr, 5/2
day or 7 day).
TS715-Si models are double insulated and do not require
an earth connection, however a parking terminal is
provided on the wallplate. This is clearly marked with an
Earth symbol.
the rear of the plug-on module must be set. See diagram
below for available options.
top of wallplate in apertures on rear of module, hinge
down and press fi rmly to wallplate before tightening
securing screws on bottom of wallplate. Before mounting
the unit, ensure the 4 DIL switches on the rear have been
moved to the required settings.
Sw.1
Not Used
Sw.2
Not Used
5/2 Day
Sw.3
Sw.4
7 Day
INSTALLER SETTING
24 Hour
5+2 Day
7 Day
Not Used
Not Used
7 Day or 24 Hour
24 Hour
33