Thermostat Mounting; Wiring Guide — Heat Pump Systems - Honeywell FocusPRO TH6000 Series Installation Manual

Focuspro th6000 series
Hide thumbs Also See for FocusPRO TH6000 Series:
Table of Contents

Advertisement

Available languages

Available languages

Wiring
Wiring guide — heat pump systems
Shaded areas below apply only to
1H/1C Heat
Pump System
Rc
Power
[1]
R
[R+Rc joined by jumper]
Y
Compressor contactor
C
O/B
Changeover valve
G
Fan relay
2H/1C Heat
Pump System
(TH6220D
only)
[8]
Rc
Power
[1]
R
[R+Rc joined by jumper]
Y
Compressor contactor
C
O/B
Changeover valve
G
Fan relay
Aux/E Auxiliary/Emergency heat relay
L
Sends output when set to Em. Heat
2H/1C Heat
Pump System
(TH6320U
only)
[8]
Rc
Power
[1]
R
[R+Rc joined by jumper]
Y
Compressor contactor
C
O/B
Changeover valve
G
Fan relay
Aux/E Auxiliary/Emergency heat relay
L
Sends output when set to Em. Heat

Thermostat mounting

Align the 4 tabs on the wallplate with
then push gently until the thermostat
snaps in place.
Push excess wire back into
the wall opening.
Plug wall opening with
non-flammable insulation.
TH6320U/TH6220D
G
C
Y
R
Rc
MCR29448
L
Aux
G
C
Y
R
Rc
E
MCR29449A
[11]
L
Aux
G
C
Y
R
Rc
E
MCR29450
[11]
or as otherwise noted.
2H/2C Heat
Pump System
(TH6320U
only)
[9]
Rc
Power
[1]
R
[R+Rc joined by jumper]
Y
Compressor contactor (stage 1)
C
O/B
Changeover valve
G
Fan relay
Y2
Compressor contactor (stage 2)
L
Sends output when set to Em. Heat
3H/2C Heat
Pump System
(TH6320U
only)
[10]
Rc
Power
[1]
R
[R+Rc joined by jumper]
Y
Compressor contactor (stage 1)
C
O/B
Changeover valve
G
Fan relay
Aux/E Auxiliary/Emergency heat relay
Y2
Compressor contactor (stage 2)
L
Sends output when set to Em. Heat
See
[notes]
on page 4.
5
FocusPRO
TH6000 Series
®
L
Y2
G
C
L
Y2
Aux
G
C
E
MCR29453
69-2695EFS— 01
Y
R
Rc
MCR29451
[11]
Y
R
Rc
MCR29452
[11]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Focuspro th6110dFocuspro th6220dFocuspro th6320u

Table of Contents