3. Put the Top Cover on the ProCam and then retest.
Note: If necessary, repeat this procedure moving the Opening Blade Spring
one notch at a time and replacing the Top cover each time before re-
testing.
4. When the Hybrid Test reading is within specification, replace the Top Cover.
Note: If changing the tension on the Opening Blade Spring fails to bring the
readings into specification, refer to steps 3 and 4 of the Hybrid (ZLS/
Blade Speed) Test procedure on page 2-14.
CHANGE POSITION OF
SPRING IN RACK TO
AFFECT BLADE SPEED
Figure 2-7. Hybrid Test Adjustment (Opening Blade Spring Tension Adjustment)