j. Carefully remove the IR and Visible Light Calibration Slides, noting
orientation and order for future reassembly (Figure 3-41).
k. Using tweezers and wearing lintless gloves or finger cots, carefully
remove the shutter blades, noting orientation and order. Suggestion: put
them aside on a clean surface, in the position and order removed
(Figure 3-41).
SHUTER SLIDES
NO. 3
BASEBLOCK
Figure 3-41. Removing Calibration Slides and Shutter Blades
l. To remove the Drive Link, use a greenstick or narrow screwdriver and
work from the rear of the Baseblock: lift the catch finger on the Drive
Link and remove it from the front (Figure 3-42). Keep Link from
being caught under end of Solenoid 1 coil winding. Solenoid 1 plunger
will drop out — don't lose it.
IR CAL SLIDE
NO. 1
NO. 2
3 - 41
VISIBLE LIGHT CAL SLIDE
(NOTE ORIENTATION
WHEN MOVING)
CLEAN SURFACE