nord BU 0135 Starter Manual

Motor starter sk 105e...175e
Table of Contents

Advertisement

Quick Links

Additional information to BU 0135, V2713
NOTICE
Please regard the additional information attached at the end of the document concerning:
UL – Gruppenabsicherung / group fusing (TI 80_0013)
Bargteheide, 08.12.2014
Getriebebau NORD GmbH & Co. KG
Getriebebau-Nord-Straße 1 • 22941 Bargteheide, Germany • http://www.nord.com/
Fon +49 (0) 45 32 / 289-0 • Fax +49 (0) 45 32 / 289-2253
Modification of BU 0135

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BU 0135 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for nord BU 0135

  • Page 1 • UL – Gruppenabsicherung / group fusing (TI 80_0013) Bargteheide, 08.12.2014 Getriebebau NORD GmbH & Co. KG Getriebebau-Nord-Straße 1 • 22941 Bargteheide, Germany • http://www.nord.com/ Fon +49 (0) 45 32 / 289-0 • Fax +49 (0) 45 32 / 289-2253...
  • Page 2 BU 0135 SK 105E…175E Motor Starter Manual...
  • Page 3 4. Installation Further information can be found in this documentation. The installation and cooling of the equipment must be implemented according to the regulations in the corresponding documentation. These safety instructions must be kept in a safe place! BU 0135 GB-2713...
  • Page 4 Commissioning (commencement of the intended use) is not permitted until it has been ensured that the machine complies with the EMC Directive 2004/108/EEC and that the conformity of the end product meets the Machinery Directive 2006/42/EEC (observe EN 60204).  Getriebebau NORD GmbH & Co. KG, 2013 BU 0135 GB-2713...
  • Page 5: Table Of Contents

    3.2 Overview of external control devices ..............43 4 COMMISSIONING ........................44 4.1 Factory settings ....................44 4.2 Commissioning the motor starter............... 44 4.2.1 Connection......................44 4.2.2 Configuration ......................45 4.3 AS Interface ....................... 49 4.3.1 The bus system ...................... 49 BU 0135 GB-2713...
  • Page 6 7.5 Operation with FI circuit breakers ............... 83 8 ADDITIONAL INFORMATION ....................84 8.1 Maintenance and servicing information .............. 84 8.1.1 Maintenance Instructions ..................84 8.1.2 Repair information ....................84 8.2 Abbreviations in this manual ................85 9 KEYWORD INDEX ........................86 BU 0135 GB-2713...
  • Page 7: General Information

    SK 105E…175E Motor Starter Manual General information The SK 1x5E series is based on the tried and tested NORD platform. These devices feature a compact design with optimum characteristics. Due to dual phase control, not only a pure motor start, but also a soft start is possible. The phase control process was selected so that the resulting harmonic torques are kept as low as possible.
  • Page 8: Overview

    If there is any damage, contact the carrier immediately and carry out a thorough assessment. Important! This also applies even if the packaging is undamaged. Only available on request and as an alternative to the ASI interface. BU 0135 GB-2713 Pre-series version...
  • Page 9: Scope Of Supply

    1.3 Scope of supply Standard version: IP55 (optionally IP66) Operating instructions as PDF file on CD-ROM including NORD CON (PC parameterising software) Available accessories: Matching RJ12 to SUB-D9 adapter cable to connection to a PC (Selection) RS485-RS232 conversion for connecting control boxes...
  • Page 10: Safety And Installation Information

    IEC EN 60947-4-2. In a domestic environment, this product can cause high frequency interference, in which case the user may be required to take appropriate measures. An appropriate measure would be the inclusion of a recommended mains filter. BU 0135 GB-2713 Pre-series version...
  • Page 11: Certifications

    „The torque value for the field wiring terminals for mains circuit terminals, motor terminals, break terminals and breaking resistor terminals must be 11 … 15 lb-in (1.2 … 1.5Nm). The torque value for the field wiring terminals for control circuit terminals must be 4.4 … 5.3 lb-in (0.5 … 0.6Nm).” Pre-series version BU 0135 GB-2713...
  • Page 12: C-Tick Labelling

    1 General 1.5.3 C-Tick labelling N 23134 NORD SK 1x5E series motor starters fulfill all the relevant regulations in Australia and New Zealand. 1.5.4 RoHS compliance SK 1x5E series motor starters are designed to be RoHS compliant according to Directive 2002/95/EEC...
  • Page 13: Nomenclature / Type Codes

    Optional terminal box module Optional module SK TU4-xxx (-…) The type designation resulting from this type code can be obtained from the name plate which is attached to or printed on the relevant module. Pre-series version BU 0135 GB-2713...
  • Page 14: Type Code For Basic Unit

    Option series: TU4 = external Technology Unit, CU4 = = internal customer unit *) The voltage depends on the motor starter used; please also refer to the technical data. (...) Options, only implemented if required. BU 0135 GB-2713 Pre-series version...
  • Page 15 SK 105E…175E Motor Starter Manual Optional external Technology Unit, SK TU4-… Optional internal Customer Unit, SK CU4-… Pre-series version BU 0135 GB-2713...
  • Page 16: Version With Protection Class Ip55 / Ip66

    Wherever possible, the cables should be inserted so that water is deflected away from the device (if necessary use loops). This is the only way to ensure permanent compliance with the required protection class. BU 0135 GB-2713 Pre-series version...
  • Page 17: Assembly And Installation

    The external dimensions of both sizes are identical. Size 1 is matched to motor size 80-100. Size 2 is matched to motor size 132. Motor-mounted version Wall-mounted version Pre-series version BU 0135 GB-2713...
  • Page 18: Mounting The Housing Box

    Mount the cast housing on the terminal box base of the NORD motor using the existing screws and seal as well as the enclosed toothed / contact washers. Position the cast housing with the dome facing the A-side of the motor (looking towards the A bearing cover).
  • Page 19: Adapters For Different Motors

    Adapter plate Seal Motor Size 71 Example NOTE The adaptability of motors from other manufacturers must be checked individually! Information for the conversion of controlled drive units to the SK 1x5E can be found in BU0320. Pre-series version BU 0135 GB-2713...
  • Page 20: Installation Of The Motor Starter

    For the cable gland of the connecting cable, appropriate screwed connections for cable cross-section must be used. Motor starter size Screw size Tightening torque Size I M5 x 25 3.5Nm ± 20% Size II M5 x 25 3.5Nm ± 20% BU 0135 GB-2713 Pre-series version...
  • Page 21: Option Locations In The Device

    2.2 Dimensions of the motor starter 2.2.1 Power rating / Motor size Mains / Power category SK 1x5E Size 3~ 200-240V 3~ 380-500V Size I 0.12 ... 1.5kW 0.25 ... 3.0kW Size II 2.2 ... 4.0kW 4.0 ... 7.5kW Pre-series version BU 0135 GB-2713...
  • Page 22: Sk 1X5E Mounted On Motor

    Size II Size 112 ** 219.5 Size 132 S / M 216.5 373 / 411 All dimensions in [mm] *) including additional adapter and seal (18mm) [275119050] **) including additional adapter and seal (20mm) [275274321] BU 0135 GB-2713 Pre-series version...
  • Page 23: Sk 1X5E For Wall-Mounting

     Size I  SK TIE4-WMK-1 Part No. 275 274 000 Size II  SK TIE4-WMK-2 115,5 Part No. 275 274 001 All dimensions in [mm] All possible installation orientations are permissible for wall mounting. Pre-series version BU 0135 GB-2713...
  • Page 24: Wiring Guidelines

    With the use of a ParameterBox SK PAR-3H this must never be simultaneously connected to the motor starter and the PC, as potential shifts may cause damage, especially to the PC. (See also Manual BU0040) BU 0135 GB-2713 Pre-series version...
  • Page 25: Electrical Connection

    3. Carefully lift the housing cover vertically from off the housing box. 4. The electrical connections and the option slots are now freely accessible. 5. Replace the cover 6. Evenly tighten the Allen screws in a cross-wise direction. Pre-series version BU 0135 GB-2713...
  • Page 26: Electrical Connection Of The Power Unit

    Only use copper cables with temperature class 80°C or equivalent for connection. Higher NOTE: temperature classes are permissible. This device produces high frequency interference, which may make additional suppression ATTENTION: measures necessary in domestic environments. (Details in Section. 7.3 / 7.4 (EMC)) BU 0135 GB-2713 Pre-series version...
  • Page 27: Mains Connections (L1, L2, L3, Pe)

    Tightening torque: 1.2 ... 1.5Nm Main Main 2.5.2 Motor cable (U, V, W, PE) Connection cross-section: 0.5 ... 10mm rigid/ flexible cable AWG 20-6 Tightening torque: 1.2 ... 1.5Nm Main Main Pre-series version BU 0135 GB-2713...
  • Page 28: Electro-Mechanical Brake

    P107 / P114 (brake application time / release time ) must be adjusted. In order to prevent damage to the brake control, a value ≠ 0 must be set in parameter (P107). The following settings for (P107/P114) are recommended for NORD brakes: BRE5, BRE10, BRE40 : 0.02s,...
  • Page 29: Electrical Connection Of Sk 1X5E Control Unit

    For the supply of the motor starter and the connected options. Maximum consumption by the basic device, without connected options and digital output loads (approx. 50mA for SK 105E…135E and SK 145E…175E with optional AS interface, 100mA for SK145E…175E with optional PROFIBUS) Pre-series version BU 0135 GB-2713...
  • Page 30: Sk 1X5E Control Terminal Versions

    DOUT2, digital output 2 TF-, motor thermistor (PTC) connection TF-, motor thermistor (PTC) connection TF+, motor thermistor (PTC) connection TF+, motor thermistor (PTC) connection *) In the state as delivered, this input is not used BU 0135 GB-2713 Pre-series version...
  • Page 31: Details Of The Sk 1X5E Control Connections

    P107, 400V~ 180V= depends on the supply voltage to P114, the SK 1x5E. 460/480V~ 205V= Brake control It is essential to take the correct brake coil voltage into account in Current: max. 0.5A the selection. Pre-series version BU 0135 GB-2713...
  • Page 32: Control Connections For Sk 1X5E Communication

    RJ12: Pin No. 1 … 6 1: n.c. +24V 24V supply voltage 2: n.c. from the FI 3: GND 24V  20% 4: RS232_TxD 5: RS232_RxD 6: +24V SK145E…SK175E with integrated AS interface SK145E…SK175E with integrated PROFIBUS BU 0135 GB-2713 Pre-series version...
  • Page 33: Plug Connectors

    For motor-mounted starters it is possible to mount a mains output plug in place of the motor connection. Via this, the mains voltage can be looped to the next device. ATTENTION The permissible current load for the connection terminals, plugs and supply cables must be observed when looping the mains voltage. Pre-series version BU 0135 GB-2713...
  • Page 34: Plug Connectors For Control Connection

    The protection class (IP67) of the plug connector only applies in the screwed state. The cover caps correspond to the colour version as does the plastic body of the plug connector. BU 0135 GB-2713 Pre-series version...
  • Page 35 *PIN 1 and PIN 3 areonly assigned in the M12-flanged socket M12 flanged plug to connect the outgoing PROFIBUS DP cable Pin designation of M12 plug The pin designations of the M12 socket are the corresponding mirror image. Pre-series version BU 0135 GB-2713...
  • Page 36: Atex Zone 22 For Sk 1X5E (In Preparation)

    Only the original seals may be used. The protective film covering the diagnostic LEDs in TU4 modules must not be damaged. Repairs may only be carried out by Getriebebau NORD. BU 0135 GB-2713 Pre-series version...
  • Page 37: Modified Sk 1X5E For Compliance With Category 3D

    Only a modified motor starter is permissible for operating an SK 1x5E in the ATEX Zone 22. This adaptation is only made at the NORD factory. In order to use the motor starter in ATEX Zone 22, among other things, the diagnostic caps are replaced with aluminium / glass versions.
  • Page 38 SK CSX-3H 275281013 SK PAR-3H 275281014 ATTENTION The diagnostic opening of the basic unit for the connection of a hand-held technology unit or a PC must not be opened in an atmosphere containing explosive dust. BU 0135 GB-2713 Pre-series version...
  • Page 39: Commissioning Information

    Setting value Factory setting Description P203 Data according to rating If a 4-pole NORD motor is not used, the nominal [xxx] plate current on the rating plate must be entered here. Motor data The I²t- monitoring of the motor must be switched...
  • Page 40: Ec Declaration Of Conformity (In Preparation)

    2 Assembly and installation 2.8.4 EC Declaration of Conformity (in preparation) BU 0135 GB-2713 Pre-series version...
  • Page 41: Outdoor Installation

    If it is fitted in an M16 cable gland of the motor starter, care must be taken that the diaphragm valve does not come into contact with standing water. Pre-series version BU 0135 GB-2713...
  • Page 42: Display And Control

    For more complex tasks, connection to a PC system and the use of NORD CON parameterisation software is available. The cover of the device must be removed in order to access the diagnostic interface.
  • Page 43: Diagnostic Leds On The Motor Starter

    NOTE If there is active RS232 communication to a PC (NORD CON) or connected control boxes, the device status cannot be displayed. In this case the LED indi- cates that there is communication and in general is therefore always "green".
  • Page 44: Overview Of External Control Devices

    RS232 signal of the starter Part No. 275274603 RS232 Data sheet TI 275274603 (www.nord.com) Installation of the control unit is performed as follows: 1. Remove the housing cover (see Section 2.4). 2. Connect the RJ12-RJ12 cable between the control unit and the RS485 socket of the converter (SK TIE4-RS485-RS232) (see the arrow in the adjacent illustration).
  • Page 45: Commissioning

    Commissioning 4.1 Factory settings All motor starters supplied by Getriebebau NORD are pre-programmed with the default setting for standard applications with 4 pole standard motors (same voltage and power). The nominal current for the particular motor circuit according to the type plate must be set as the nominal current in parameter P203. This can be carried out via potentiometer P1 or by parameterisation.
  • Page 46: Configuration

    S1. For extended functions or for diagnostic purposes it may be necessary to adjust or view individual parameters. The use of a ParameterBox (SK CSX-3H / SK PAR) or NORD CON software is necessary to change the parameters. The most important parameters are listed below:...
  • Page 47 For soft starters (not reversing soft starters) the deceleration time is set with P2 and the acceleration time is set with P4. Otherwise, P4 is used to set the acceleration and deceleration times (SK 115 / SK 155). Pre-series version BU 0135 GB-2713...
  • Page 48 01: Deceleration mode 2 10: Deceleration mode 3 11: Deceleration mode 4 * For SK 135E and SK 175E devices the function "Switch off with error on overtemperature" can only be ena- bled via parameter P580. BU 0135 GB-2713 Pre-series version...
  • Page 49 Setpoint Integrated potentiometer P1 L1 - L2/N - L3 115/230/400V Frequency ramp Integrated potentiometer P2 Controller enable External switch S1 Motor starters Motor starters SK 1x5E - ... SK 105E-…. 24V= Switch S1 Motor PTC Pre-series version BU 0135 GB-2713...
  • Page 50: As Interface

    21ms. The bus system is completely defined in the AS-Interface Complete Specification and is standardised as per EN 50295, IEC62026. BU 0135 GB-2713 Pre-series version...
  • Page 51: Features

    AS-i master in order to keep the voltage drop as small as possible. No supply of the device via AS interface Permissible total current for supply of the AS interface and the device via the yellow cable. Pre-series version BU 0135 GB-2713...
  • Page 52 It is essential that the PE connection of the AS interface mains unit (if present) is earthed. The brown AS-i+ and the blue AS-i- wire from of the AS interface cable must not be earthed. BU 0135 GB-2713 Pre-series version...
  • Page 53: Commissioning Of The As Interface

    (24V) for the use of the digital inputs or other external peripherals (e.g. activators) can be obtained from terminals 43/40. The total permissible current for this is limited to 165mA if the supply is only via the yellow AS-i cable! Pre-series version BU 0135 GB-2713...
  • Page 54 Therefore a version must be selected, which is matched to the outline conditions of the motor starter. BU 0135 GB-2713 Pre-series version...
  • Page 55 AS-i AS-i cable cable. AS-i addressing unit NOTE If the AS-i and the starter control unit are supplied separately (yellow and black cable), battery-operated addressing units are sufficient. Pre-series version BU 0135 GB-2713...
  • Page 56: Technical Data For As Interface

    In order to prevent a re-start on restoration of communication, the AS-i master must active- ly set the control bits to "Zero". For control via the AS interface, acknowledgement is not automatically performed by a flank on one of the enable inputs BU 0135 GB-2713 Pre-series version...
  • Page 57: Profibus

    Pin 83 = PBRA  Pin 82 = PBRB NOTE In case of direct connection to the terminals, there must not be any spur cables, i.e. the incoming and outgoing cables must be connected to the terminals together! Pre-series version BU 0135 GB-2713...
  • Page 58: Addressing

    Switch S2 = 4 Switch S3 = 2 Resulting PROFIBUS address = 42 NOTE A subsequent change to the address only comes into effect after the mains supply to the motor starter is switched on again! BU 0135 GB-2713 Pre-series version...
  • Page 59: Displays

    If this is the last participant on the bus, is the termination resistor switched in?  PLC switched on and configured with the correct GSD file (NORD0DA5.gsd)?  Does the address which is configured in the PLC match the address which is set on the starter? Pre-series version BU 0135 GB-2713...
  • Page 60: Process Data

    In case of malfunction (interruption of communication or break in the PROFIBUS cable) the motor starter switches off automatically. In order to prevent a re-start on restoration of communication, the PROFIBUS master must actively set the control bits to "Zero". BU 0135 GB-2713 Pre-series version...
  • Page 61: Parameterisation

    Parameter number Description Parameter value range Factory settings of parameter Due to certain configurations, the parameters are subject to certain conditions. The following tables (from Section 5.1 onwards) list all parameters together with the relevant information. Pre-series version BU 0135 GB-2713...
  • Page 62: Parameter

    According to the setting of parameter P130, the parameter can either only be read or FLASH can be changed and saved in the flash memory. FLASH The parameter is read out of the flash memory and can be changed. BU 0135 GB-2713 Pre-series version...
  • Page 63: Operating Displays

    1 = All parameters are visible { 1 } 2 = ... 9999, (except 65) only parameters P001 and P003 are visible. In the following, supervisor parameters are designated with "S"; normal parameters are designated with "x" Pre-series version BU 0135 GB-2713...
  • Page 64: Basic Parameters

    If P114=0, the value which is set here also applies for the release time (P114) NOTE: For lifting gear applications, with brakes which are applied very slowly, a slight sagging of the load cannot be prevented, as the motor usually switches off before the brake is applied BU 0135 GB-2713 Pre-series version...
  • Page 65 1 = Oscillation optimised, the phase control is performed so that in the case of an idling motor and a long ramp time, there is as little oscillation as possible. Pre-series version BU 0135 GB-2713...
  • Page 66 As for operating mode 3, however the brake is applied with a delay, which is determined by the value from potenti- [P215] ometer 4 / P107. P4 / [P103] P3 / [P210] P4 / [P102] BU 0135 GB-2713 Pre-series version...
  • Page 67: Motor And Characteristic Curve Parameters

    Time limit for the boost lead: Time of effect for the increased starting torque. The resulting acceleration time, which is required until full voltage is achieved is then calculated according to: { 0.00} P102 P216. Pre-series version BU 0135 GB-2713...
  • Page 68: Control Terminals

    Acceleration time for type SK 115E and SK 155E devices (5) – Locking time for all other devices (2) Deceleration time for type SK 115E and SK 155E devices (6) – Ramp time for all other devices (4) The thermistor input cannot be re-programmed to another function. BU 0135 GB-2713 Pre-series version...
  • Page 69 Phase sequence detection { [-04] = 6 } Release the brake 4 = Overtemperature switch-off on error. Switch-off mode Bit 0 Switch-off mode Bit 1 The function of the output for the mechanical brake cannot be changed. Pre-series version BU 0135 GB-2713...
  • Page 70: Additional Parameters

    1.5 x overcurrent for 240sec 2 = Class 20, 1.5 x overcurrent for 360sec ATTENTION The motor I2t circuit breaker cannot replace protection with an external fuse against short circuit or a short to earth! BU 0135 GB-2713 Pre-series version...
  • Page 71 NOTE: As long as P130=0 is set, P570 is determined by potentiometer P2. In this case, the parameter can only be read and not changed and corresponds to the value which is set by the potentiometer. Pre-series version BU 0135 GB-2713...
  • Page 72 NOTE: As long as P130=0 is set, for devices without a soft start function (105E, 125E, 145E and 165E) P582 is determined by DIP switch 3. In this case, the parameter can only be read and not changed and corresponds to the value which is set by the DIP switch. BU 0135 GB-2713 Pre-series version...
  • Page 73: Information

    0000 0000 Binary Minimum value 0111 1111 Binary Maximum value SimpleBox: The binary Bits are converted into a hexadecimal value and displayed. ParameterBox: The Bits are displayed with increasing values from right to left (binary). Pre-series version BU 0135 GB-2713...
  • Page 74 Current voltage P722 (Actual voltage) 0 ... 500 V Displays the actual AC voltage supplied by the motor starter output. Voltage -d P723 (Actual voltage component Ud) 0 ... 500 V Usually this value is "0" BU 0135 GB-2713 Pre-series version...
  • Page 75 [-06] = Parameter data In 2 Data during parameter transfer: Order [-07] = Parameter data In 3 label (AK), Parameter number (PNU), Index (IND), Parameter value (PWE1/2) [-08] = Parameter data In 4 [-09] = Parameter data In 5 Pre-series version BU 0135 GB-2713...
  • Page 76 (U phase voltage) 0 ... 999 V Displays the actual U phase voltage. NOTE: This value can deviate somewhat from the value in P722, due to the measurement procedure used, even with symmetrical output currents. BU 0135 GB-2713 Pre-series version...
  • Page 77 (Phase W voltage) 0 ... 999 V Displays the actual W phase voltage. NOTE: This value can deviate somewhat from the value in P722, due to the measurement procedure used, even with symmetrical output currents. Pre-series version BU 0135 GB-2713...
  • Page 78: Operating Status Messages

    "Error" state. Display of the message is suppressed if the warning appears during parameterisation. The current warning message can be displayed in detail at any time in array element [-02] of parameter (P700). BU 0135 GB-2713 Pre-series version...
  • Page 79: Table Of Possible Error Messages

    Use additional external mains filter. (Section 7.3 / 7.4 EMC) (EEPROM error) The motor starter must be very well earthed. 20.9 Memory Protection Error 21.0 NMI error (not used by hardware) 21.1 PLL error 21.2 ADU error 21.3 PMI error 21.4 Userstack overflow Pre-series version BU 0135 GB-2713...
  • Page 80: Table Of Possible Warning Messages

    Enable signal was already present during the initialisation phase (after mains "ON" or control voltage "ON"). Only issue enable signal after completion of initialisation (i.e. when the motor starter is ready) Activation of "Automatic Start" (P428) I006 Mains voltage error Mains failure BU 0135 GB-2713 Pre-series version...
  • Page 81: Technical Data

    , with wiring sleeves 1.5mm terminals 1.2...1.5Nm RS485 / RS232 1x RJ12 (6-pin) 24V - Output 24V DC ±25%, max. 200mA (Terminal 43) Digital output 18…30V DC, according to supply voltage (Terminal 44) , max. 200mA Pre-series version BU 0135 GB-2713...
  • Page 82: Motor Starter Electrical Data

    Max. permissible ambient temp. with nominal output current 50°C 50°C 60°C 60°C 70%ED 10min 60°C 60°C 70%ED 10min (100% / 20%Mn) * Circuit Breaker (inverse time trip type) as per UL489 ** FLA (S1-40 °C) BU 0135 GB-2713 Pre-series version...
  • Page 83: Electromagnetic Compatibility

    SK 1x5E motor starters are designed solely for commercial applications. They are therefore not subject to the requirements of the standard EN 61000-3-2 for radiation of harmonics. This device produces high frequency interference, which may make additional suppression measures necessary in domestic environments. Pre-series version BU 0135 GB-2713...
  • Page 84: Emc Limit Value Classes

    3%; 2% changes Wiring recommendations for mounting near to motor 7.5 Operation with FI circuit breakers The motor starters can be operated with leakage current circuit breakers. The leakage current is less than 20 mA BU 0135 GB-2713 Pre-series version...
  • Page 85: Additional Information

    Tjüchkampstraße 37 26605 Aurich, Germany For queries about repairs, please contact: Getriebebau NORD GmbH & Co. KG Tel.: 04532 / 289-2515 Fax: 04532 / 289-2555 If a motor starter is sent in for repair, no liability can be accepted for any added components, e.g. such as mains cables, potentiometer, external displays, etc.!
  • Page 86: Abbreviations In This Manual

    This is important in order to keep repair times as short and efficient as possible. On request you can also obtain a suitable return goods voucher from Getriebebau NORD. Unless otherwise agreed, the device is reset to the factory settings after inspection or repair.
  • Page 87: Keyword Index

    EMC ........10, 82 Characteristic curves ....65 Mains connection ......26 Emerg. stop Error (P427) ... 67 Check input voltage (P538) ..70 Mains frequency (P718)....73 Emission of interference ..... 83 Commissioning ......44 Pre-series version BU 0135 GB-2713...
  • Page 88 Warnings ......42, 77, 79 Plug connectors for control Standard version ......8 Weight ......... 21 connection ......33 Starting disabled ......79 Wiring guidelines ......23 Plug connectors for power Starting voltage (P210) ....66 connections ......32 BU 0135 GB-2713 Pre-series version...
  • Page 89 SK 105E…175E Motor Starter Manual Pre-series version BU 0135 GB-2713...
  • Page 90 Produktreihe Dokument Ausgabe Kapitel Seite (Product Series) (Document) (Issue) (Section) (Page) SK 135E BU 0135 2713 SK 105E, SK 115E, … SK 175E) SK 180E BU 0175 2314 (SK 180E, SK 190E) SK 200E BU 0200 2314 (SK 200E, SK 205E, …...
  • Page 91 Electronics – Gruppenabsicherung / group-fusing “Suitable for motor group installation on a circuit capable of delivering not more than 65000 rms symmetrical amperes, 480 V max” “When Protected by Circuit Breaker (inverse time trip type) in accordance with UL 489, rated ______ Amperes, and 500 Volts”, as listed below. device Fuse size Rated Voltage...

Table of Contents