Page 1
B 1091 – en Motors Operating and Assembly Instructions...
Page 2
Observe the applicable information signs located on the device. The installation and cooling of the equipment must be implemented Further information can be found in this documentation. according to the regulations in the corresponding documentation. These safety instructions must be kept in a safe place! B 1091 en-2722...
Page 3
Documentation Pos : 3 /Anl eitung en/Motor en/B1091 Drehstr ommotor en/1. Allgemei nes /0. Pr olog/D ok umentati on - Versionsliste [B 1091] @ 76\m od_1625229689983_388.doc x @ 2802601 @ @ 1 Documentation Title: B 1091 Order no.: 6051302 Series: Asynchronous motors / synchronous motors •...
Page 4
People's Republic of China B 1091, 6051302 / 1221 • General corrections March 2021 B 1091, July 6051302 / 2721 • Supplement to section 2021 – Explosion-protected electric motors according to Class I Div.2 – Explosion-protected electric motors according to Class II Div.2...
Page 5
Pos : 5 /Allgemei n/Allgemei ngültige Modul e/H erausgeber @ 67\m od_1613484928402_388.docx @ 2738552 @ @ 1 Publisher Getriebebau NORD GmbH & Co. KG Getriebebau-Nord-Straße 1 • 22941 Bargteheide, Germany • http://www.nord.com Fon +49 (0) 45 32 / 289-0 • Fax +49 (0) 45 32 / 289-2253 Member of the NORD DRIVESYSTEMS Group === Ende der Liste für T extm arke Copyright ===...
Page 6
Motors – Operating and Assembly Instructions B 1091 en-2722...
Repairs ..........................30 3.1.9 Painting ..........................30 3.1.10 Name plate of NORD Ex eb motors according to EN IEC 60079-0:2018 ......31 3.1.11 Applied standard versions ....................31 Motors with ignition protection class Non Sparking Ex ec ..............32 3.2.1 Cable glands........................
Page 8
3.4.6 Incremental encoder ......................48 3.4.7 Overview of brake attachment for NORD ATEX motors ............. 48 3.4.8 Name plate of motors (Ex tb, Ex tc) according to EN 60079 for FI operation ..... 49 Motors according to TP TC012/2011 for the Eurasian Economic Union .......... 50 3.5.1...
Pos : 11 /Anl eitungen/M otoren/B1091 Drehstromm otoren/1. Allgem eines/!1! Allgem eines _Inhalt @ 7\m od_1431330112564_388.docx @ 217304 @ @ 1 These operating instructions must be read before NORD motors are transported, installed, commissioned, serviced or repaired. All persons who are involved in these tasks must observe these operating instructions.
Indicates a possibly harmful situation, which may cause damage to the NOTICE product or the environment. Note Indicates hints for use and useful information. Pos : 15 /Allgem ein/Allgem eing ültige M odul e/---------- Seitenum bruc h ---------- @ 1\m od_1329145698658_0.docx @ 15891 @ @ 1 B 1091 en-2722...
To prevent such injuries, allow sufficient time for cooling down before starting work - the surface temperature should be checked with suitable measuring equipment. In addition, keep sufficient distance from adjacent components during installation, or install protection against contact. B 1091 en-2722...
In principle the conditions of use and the ambient conditions determine the necessary protection class and any other additional measures. For outdoor installation and vertical versions, e.g. V1 or V5 with the shaft pointing downwards, Getriebebau NORD recommends the use of the double fan cover option [RDD].
The generally required measures for protection against touching the drive elements must be observed. If a motor is started without a drive element, the parallel key must be secured against being thrown out. This also applies for any second shaft end. Alternatively, the parallel shaft key must be removed. B 1091 en-2722...
) and radial forces (F ) for the A side end of the motor shaft can be obtained from the table below. Getriebebau NORD should be consulted if the radial force (F ) is applied at a distance which is greater than the length E/2.
In principle, attention must be paid to an EMC-compliant installation. Additional information on operation on the frequency inverter, in particular information on the max. permissible speed, the thermal design and the possible torques, can be found in the current NORD motor catalogue M7000.
Information Electromagnetic compatibility NORD motors comply with the EU-Directive 2014/30/EU. Assembly or installation work must not cause impermissible interference. Immunity from interference must still exist. Production of interference: In cases of large differences of torque (e.g. when driving a piston compressor) a non-sine wave motor current is induced, whose harmonics can cause an impermissible effect on the mains and therefore impermissible production of interference.
Condensation outlets must always be located at the lowest point of the motor. During installation of the motor care must be taken that the condensation outlets point downwards and are closed. Open condensation outlets cause a reduction of the protection class. B 1091 en-2722...
Perform a winding insulation resistance measurement The general overhaul must be carried out by qualified personnel in a specialist workshop with appropriate equipment. We urgently recommend that the general overhaul is carried out by the NORD Service department. If the drive unit is used in special ambient conditions, the above-mentioned intervals may be significantly shorter.
In addition to the labelling of the motor, observe any labelling on the attached components and devices. Consider any resulting restrictions for the entire drive. Explosive gas mixtures or dust concentrations may cause severe or fatal injuries in combination with hot, electrically live and moving components of electrical machines. B 1091 en-2722...
Check that the terminal nuts and the screw for the earth lead are tight before closing the terminal box. The terminal box seals and the seals of the cable glands must be correctly seated and must not be damaged. B 1091 en-2722...
For an inclination of less than 20°, an appropriate protective device, which meets the above mentioned conditions, must be provided by the operator / installer. A hand wheel on the second shaft end is not permitted. B 1091 en-2722...
If the effective value of the shaft voltage (RMS) exceeds 250 mV, permissible technical measures must be taken. If necessary, please contact the NORD service. Please also pay attention to the relevant PTB data sheets. In addition to further information, details on the permissible frequency characteristic curves can be found here.
Operation with a frequency inverter must be explicitly certified. The separate manufacturer's information must be observed. The EMC Directive must be complied with. Pos : 73 /Allgem ein/Allgem eing ültige M odul e/---------- Seitenum bruc h ---------- @ 1\m od_1329145698658_0.docx @ 15891 @ @ 1 B 1091 en-2722...
Pos : 74 /Anl eitungen/M otoren/B1091 Drehstromm otoren/3. AT EX/Reparaturen [EXE, EXN] @ 7\m od_1431422270100_388.docx @ 218512 @ 3 @ 1 3.1.8 Repairs Repairs must be carried out by Getriebebau NORD or by an officially recognised expert. The work must be indicated with an additional repair plate. With the exception of standard, commercially available and equivalent components, only original spare parts (see spare parts list) may be used.
Pos : 78 /Anl eitungen/M otoren/B1091 Drehstromm otoren/3. AT EX/Ty pensc hild N ORD Ex eb- M otoren nach EN 60079 [EXE] @ 72\m od_1619623980393_388.doc x @ 2772275 @ 3 @ 1 3.1.10 Name plate of NORD Ex eb motors according to EN IEC 60079-0:2018...
DIN EN 60079, Part 10 provides information about this. The operator is responsible for the zone division. The use of motors which are not certified for explosion hazard areas is prohibited in explosion hazard areas. B 1091 en-2722...
Check that the terminal nuts and the screw for the earth lead are tight before closing the terminal box. The terminal box seals and the seals of the cable glands must be correctly seated and must not be damaged. B 1091 en-2722...
For an inclination of less than 20°, an appropriate protective device, which meets the above mentioned conditions, must be provided by the operator / installer. A hand wheel on the second shaft end is not permitted. B 1091 en-2722...
If the effective value of the shaft voltage (RMS) exceeds 250 mV, permissible technical measures must be taken. If necessary, please contact the NORD service. Please also pay attention to the relevant PTB data sheets. In addition to further information, details on the permissible frequency characteristic curves can be found here.
The motors are equipped with a suitable, electrostatically tested painting ex-works. Subsequent painting may only be carried out in consultation with Getriebebau NORD or a repair workshop approved for the repair of explosion-protected electric motors. The valid standards and regulations must be observed.
Pos : 102 /Anleitungen/Motor en/B1091 Dr ehs tromm otoren/3. ATEX/T ypenschil d N ORD Ex ec- Motor en nac h EN 60079 [EXN] @ 72\m od_1619625291614_388.doc x @ 2772388 @ 3 @ 1 3.2.9 Type plate for NORD Ex ec motors according to EN IEC 60079-0:2018...
EX tb IIIC T125°C Db For category 2 IEC 60079 Ex tc IIIB T125°C Dc For category 3 (zone 22 – non-conducting dust) The indicated surface temperature may deviate from 125 °C and can be found on the name plate. B 1091 en-2722...
If an X has been added to the certificate, special requirements must be observed in the EU type- examination certificate, the IECEX CoC and/or the documentation to be considered. It is prohibited to use standard motors that are not certified for explosion hazard areas in explosion hazard areas. B 1091 en-2722...
The motors are equipped with a suitable, electrostatically tested painting ex-works. Subsequent painting may only be carried out in consultation with Getriebebau NORD or a repair workshop approved for the repair of explosion-protected electric motors. The valid standards and regulations must be observed.
3.3.11 Minimum cross section of bonding conductors Cross section of the phase conductor Minimum cross section of the associated of the installation S [mm protective conductor S S ≤ 16 16 < S ≤ 35 S > 35 0.5 S B 1091 en-2722...
Upon replacement of the ball bearings, the radial shaft seals must also be replaced. Please use the radial shaft seals prescribed by Getriebebau NORD. It is essential to pay attention to professional installation. The radial shaft seal’s outer ring and sealing lip must be lubricated.
Pos : 126 /Anleitungen/Motor en/B1091 Dr ehs tromm otoren/3. ATEX/Betrieb am Freq uenz umrichter [Zone22] @ 67\mod_1613487358920_388.docx @ 2739086 @ 3 @ 1 3.4.1 Operation with frequency inverters ATEX NORD motors with ignition protection classes tb and tc are suitable by their insulation system design for operation with the frequency inverter. The variable speed range requires temperature monitoring using PTC resistors.
In this context, any existing gear unit must be observed. Please contact Getriebebau NORD in case of uncertainties. If any one component of the entire drive has no Ex labelling, the entire drive must not be commissioned in explosion hazard areas.
DC voltage. The brake voltage indicated on the name plate must be complied with. The power supply lines and the temperature sensor line must not be installed together in one cable. Check the brake’s functionality before commissioning. There must be no grinding noises as impermissible heating may occur. B 1091 en-2722...
If the operating instructions are not available, contact the Getriebebau NORD service department. Pos : 133 /Anleitungen/Motor en/B1091 Dr ehs tromm otoren/3. ATEX/Ü bersicht Br ems anbau N ORD ATEX- M otoren nac h 94/9 EG @ 67\mod_1613488057199_388.docx @ 2739238 @ 3 @ 1 3.4.7 Overview of brake attachment for NORD ATEX motors...
Before commissioning, the type plate must be compared with the requirements of the aforementioned declaration, which result from the local regulations and operating conditions. Pos : 137 /Allgem ein/Allgem eingültig e Module/---------- Seitenumbr uc h ---------- @ 1\mod_1329145698658_0.docx @ 15891 @ @ 1 B 1091 en-2722...
In addition, compliance with the temperature class and the maximum surface temperature as stated on the type plate is mandatory. Pos : 141 /Allgem ein/Allgem eingültig e Module/---------- Seitenumbr uc h ---------- @ 1\mod_1329145698658_0.docx @ 15891 @ @ 1 B 1091 en-2722...
The extended ambient temperature range does not apply for optional attachments such as a brake, an encoder and/or an external fan. Contact the manufacturer in case of doubt with regard to permissibility! Pos : 145 /Allgem ein/Allgem eingültig e Module/---------- Seitenumbr uc h ---------- @ 1\mod_1329145698658_0.docx @ 15891 @ @ 1 B 1091 en-2722...
Ex II 2D Ex tb IIIC T ***°C Db Ex tD A22 IP5X T***°C Ex II 3D Ex tc IIIB T ***°C Dc Name plate examples for the labelling of NORD CCCEx motors according to the Chinese standard. Name plate example C2D Name plate example C3D Pos : 149 /Allgem ein/Allgem eingültig e Module/---------- Seitenumbr uc h ---------- @ 1\mod_1329145698658_0.docx @ 15891 @ @ 1...
Explosion hazard Opening the terminal box in an explosive atmosphere is prohibited. Installation, use, parametrisation and maintenance of explosion-protected NORD CCCEx motors must be performed by the operator in accordance with the operating and maintenance instructions B1091 and B1091-1 and in accordance with the following Chinese standards.
OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS AVERTISSEMENT RISQUE D'EXPLOSION AVANT DE DECONNECTER L'EQUIPEMENT, COUPER LE COURANT OU S'ASSURER QUE L'EMPLACEMENT EST DESIGNE 'NON DANGEREUX WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I DIV.2/CLASS II DIV.2 B 1091 en-2722...
1.5 - 2.5 3.0 – 5.0 Pos : 161 /Anleitungen/Motor en/B1091 Dr ehs tromm otoren/3. ATEX/Elektrischer Anschl uss [Zone21+ 22 + Clas s I und II Div.2] @ 7\m od_1431433133025_388.doc x @ 219085 @ 3 @ 1 B 1091 en-2722...
For an inclination of less than 20°, an appropriate protective device, which meets the above mentioned conditions, must be provided by the operator / installer. A hand wheel on the second shaft end is not permitted. B 1091 en-2722...
(e.g. thermal protection of the machine). Repairs must be carried out by Getriebebau NORD or by an officially recognised expert. The work must be indicated with an additional repair plate. With the exception of standard, commercially available and equivalent components, only original spare parts (see spare parts list) may be used.
OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS AVERTISSEMENT RISQUE D'EXPLOSION AVANT DE DECONNECTER L'EQUIPEMENT, COUPER LE COURANT OU S'ASSURER QUE L'EMPLACEMENT EST DESIGNE 'NON DANGEREUX WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I DIV.2/CLASS II DIV.2 B 1091 en-2722...
The screws for the terminal box cover must be tightened with a torque according to the list below. Tightening torques for terminal box cover screws Thread diameter Tightening torque (Nm) 0.8 - 1.2 1.2 - 1.8 1.5 - 2.5 3.0 – 5.0 B 1091 en-2722...
For an inclination of less than 20°, an appropriate protective device, which meets the above mentioned conditions, must be provided by the operator / installer. A hand wheel on the second shaft end is not permitted. B 1091 en-2722...
The motors are equipped with a suitable, electrostatically tested painting ex-works. Subsequent painting may only be carried out in consultation with Getriebebau NORD or a repair workshop approved for the repair of explosion-protected electric motors. The valid standards and regulations must be observed.
Pos : 180 /Anleitungen/Motor en/B1091 Dr ehs tromm otoren/3. ATEX/Mi ndestq uersc hnitte v on Schutzl eitern_02 [Clas s II] @ 73\m od_1620284355074_388.docx @ 2776165 @ @ 1 The minimum cross-section for connection of a cable to the outer earthing terminal is 4 mm². B 1091 en-2722...
Pos : 181 /Anleitungen/Motor en/B1091 Dr ehs tromm otoren/3. ATEX/Betrieb am Freq uenz umrichter @ 76\mod_1625221471421_388.docx @ 2802380 @ 3 @ 1 3.8.9 Operation with frequency inverters NORD motors that comply with Class II Div.2 are suitable for operation on a frequency inverter. The variable speed range requires temperature monitoring using temperature sensors. The approved speed...
Upon replacement of the ball bearings, the radial shaft seals must also be replaced. Please use the radial shaft seals prescribed by Getriebebau NORD. It is essential to pay attention to professional installation. The radial shaft seal’s outer ring and sealing lip must be lubricated.
Table of Contents 4 Replacement parts Please note our spare parts catalogue PL 1090 under www.nord.com. We will be pleased to send you the spare parts catalogue on request. Pos : 187 /Anleitungen/Motor en/B1091 Dr ehs tromm otoren/6. Konformitäts erklärungen/!1! Konformitätserkl ärungen (2022- 06- 14 09:32:19) @ 82\mod_1637149063402_388.docx @ 2845265 @ 1 @ 1...
Need help?
Do you have a question about the B 1091 and is the answer not in the manual?
Questions and answers