Download Print this page

Thermometer; To Take A Temperature Reading; To Switch A Temperature Reading Unit Between Celsius (°C) And Fahrenheit (°F - Casio 5381 Operation Manual

Advertisement

Operation Guide 5381
To change the Daylight Saving Time (summer time) setting
1. In the Timekeeping Mode, hold down A until ADJ
DST indicator
appears.
This indicates the city code setting mode.
The hour and minute hands automatically move out of
the way at this time (page E-15).
2. Press C to display the DST setting mode.
3. Press D to toggle between Daylight Saving Time (ON)
and Standard Time (OFF).
Note that you cannot switch between daylight saving
time and standard time while UTC is selected as your
Home City.
4. After the setting is the way you want, press A to
return to the Timekeeping Mode.
The DST indicator appears to indicate that Daylight
Saving Time is turned on.
E-20
2. Press C to move the fl ashing in the sequence shown below to select the other
settings.
C
C
City Code
DST
(page E-20)
(page E-18)
C
Illumination Duration
(page E-55)
C
Button Operation Tone On/Off
(page E-59)
C
E-22
Note
Resetting the seconds to 00 while the current count is in the range of 30 to 59
causes the minutes to be increased by 1.
The watch's built-in full automatic calendar makes allowances for different month
lengths and leap years. Once you set the date, there should be no reason to
change it except after you have the watch's battery replaced.
The day of the week changes automatically when the date changes.
E-24
Measurement unit: 0.1°C (or 0.2°F)
Measurement range*: –10.0 to 60.0°C (or 14.0 to 140.0°F)
* - -.- is displayed in place of the temperature when reading is outside the allowable
range.
2. Press C to return to the Timekeeping Mode.
To switch a temperature reading unit between Celsius (°C) and Fahrenheit (°F)
1. Enter the Thermometer Mode (page E-12).
2. Hold down A for at least two seconds until the temperature value disappears
from the display.
When you release A the temperature value will start to fl ash.
The hour and minute hands automatically move out of the way at this time (page
E-15).
E-26
Correcting the Temperature Reading
The temperature sensor of this watch is adjusted at the factory and so further
adjustment is not required by you. However, if you notice that the readings
produced by the watch are different from readings produced by another instrument,
you can use the procedure in this section to make corrections. You also can use
this procedure to clear a correction.
Important!
The watch will not be able to produce correct temperature readings if you make a
mistake during the correction procedure. Check to make sure that the value you
use for correction produces correct temperature readings.
Before performing the following procedure, remove the watch from your wrist and
leave it for about 20 or 30 minutes to allow the case temperature to become the
same as the air temperature.
E-28
C
12/24-Hour Format
Seconds
C
Hour
C
Minutes
C
Day
Month
Year
C
C
Adjusting the Digital Time and Date Settings
Use the procedure below to adjust the digital time and date settings.
To confi gure the digital time and date settings
1. In the Timekeeping Mode, hold down A until ADJ
appears.
This indicates the city code setting mode.
The hour and minute hands automatically move out of
the way at this time (page E-15).
3. When the timekeeping setting you want to change is fl ashing, use D and/or B
to change it as described below.
Screen
To do this:
Toggle between 12-hour (12H) and 24-hour
(24H) timekeeping
Reset the seconds to 00
Change the hour or minute
Change the year
Change the month or day
4. Press A to exit the setting mode.

Thermometer

This watch uses a temperature sensor to take temperature readings.
You can select either Celsius (°C) or Fahrenheit (°F) as the temperature
measurement unit (page E-26).

To take a temperature reading

1. In the Timekeeping Mode, press D. This will enter the
Thermometer Mode, which is indicated by TEMP on
the display.
If TEMP does not appear when you press D, press
it again (page E-12).
The temperature reading will appear about one
second after TEMP.
The reading is updated at fi ve-second intervals for two
to three minutes. After that, the watch automatically
Temperature
returns to the Timekeeping Mode.
3. Press C.
D
This will cause the current measurement
unit to fl ash.
4. Use D to select the measurement unit you
want.
5. Press A to return to the Thermometer Mode.
Important!
When TYO (TOKYO) is selected as the Home City, the temperature unit is set
automatically to Celsius (°C). These settings cannot be changed.
1. Enter the Thermometer Mode (page E-12).
2. Hold down A for at least two seconds until the temperature
value disappears from the display.
When you release A the temperature value will start to fl ash.
The hour and minute hands automatically move out of the way at
this time (page E-15).
3. Use D (+) and B (–) to calibrate the temperature value.
Calibration unit: 0.1°C (or 0.2°F)
Calibration range: –10.0 to 60.0°C (or 14.0 to 140.0°F)
Important!
To cancel a temperature reading correction setting, hold down D and B at the
same time. The watch will beep.
4. Press A to return to the Thermometer Mode.
E-21
Do this:
Press D.
Press D.
Use D (+) and B (–).
Use D (+) and B (–).
Use D (+) and B (–).
E-23
E-25
E-27
E-29

Hide quick links:

Advertisement