6. Wrap the insulation material around the connect-
ing portion.
CAUTION
Take care to arrange the piping, drain hose and
cables as the figure 7 page for inserting it into the
indoor unit and mount the indoor unit on the installa-
tion plate.
7. Wrap the tubing, the drain hose and the connect-
ing cable with tape.
8. Indoor unit installation
• Hook the indoor unit onto the upper portion of
installation plate. (Engage the two hooks of the
rear top of the indoor unit with the upper edge of
the installation plate.)
Ensure the hooks are properly seated on the
installation plate by moving it left and right.
Taping
Indoor/outdoor
connecting cable
Connecting
cable
Press the lower left and right side of the unit against the
Installation Plate until the hooks engage with their slots
(sound click).
-27-
Gas side piping
Liquid side piping
Drain hose
Connecting
cable
Drain hose