For left rear piping
3. Insert the connecting cables, the drain pipe and
connecting piping through the piping hole on
the wall.
4. Connect the piping and the indoor tubing, and
drain hose and drain pipe and place the drain
pipe into the chassis.
• Don't connect the cable to the indoor unit.
• Make a small loop for easy connection later.
• Glue up the connection portion of drain hose and
drain pipe.
Pipe Size
Liquid Side (1/4")
Gas Side (3/8")
Gas Side (1/2")
5. Bend the drain hose and bind the drain hose,
the piping and the connecting cables altogether.
Taping
Torque
1.8kg . m
4.2kg . m
5.5kg . m
Drain hose
-26-
Installation plate
Pull
Indoor
Drain hose
Drain pipe
Indoor unit tubing
Flare nut
Spanner
Torque wrench
Plastic bands
Insulation material
Drain hose
Drain pipe
Adhesive
Pull
Outdoor
Connecting cable
Connecting
piping
Pipings