Minneapolis, MN 55440 USA Phone: (800) 553--8033 or (763) 513--2850 www.nobles.com Specifications and parts are subject to change without notice. Copyright E 2007 TENNANT Company. All rights reserved. Printed in China Nobles Speed Scrub 17 - - 20 (03- -07)
WARNING: Fire Or Explosion WARNING: Spinning Brush. Hazard. Batteries Emit Hydrogen Keep Hands Away. Turn Off Gas. Keep Sparks And Open Power Before Working On Flame Away. Keep Battery Machine. Compartment Open When Charging. Nobles Speed Scrub 17 - - 20 (03- -07)
7. Main Power on/off Key Switch 3. Battery Meter 8. Hour Meter 4. Speed Control Knob (drive model) 9. FaST System on/off Switch (option) 5. Control Console Height Adjustment Lever 10. Brush Motor Circuit Breaker Button Nobles Speed Scrub 17 - - 20 (03- -07)
Maximum battery dimensions: 6.85 in / 174 mm W x 15 in / 380 mm L x 11.18 in / 284 mm H. 1. Park the machine on a level surface, remove the key and set the parking brake if equipped. Nobles Speed Scrub 17 - - 20 (03- -07)
Used for light duty scrubbing without removing floor FIG. 4 finish. 4. Connect the vacuum hose to the squeegee assembly. Loop the hose as shown using the hose clip provided (Figure 5). Nobles Speed Scrub 17 - - 20 (03- -07)
(Figure 10). FIG. 6 3. Attach the pad to the pad driver before installing pad driver (Figure 7). Secure pad with center lock. Lock Pin FIG. 10 Pad Driver FIG. 7 Nobles Speed Scrub 17 - - 20 (03- -07)
FaST system from drying out and clogging up the supply hose. WARNING: Fire or Explosion Hazard. Never Use Flammable Liquids. FOR SAFETY: When using machine, follow mixing and handling instructions on chemical containers. Nobles Speed Scrub 17 - - 20 (03- -07)
- Foam scrubbing (FaST Model): Check the FaST--PAK concentrate level. - Foam scrubbing (FaST Model): Make sure the solution tank is filled with only cool clean water, no detergents. FIG. 18 Nobles Speed Scrub 17 - - 20 (03- -07)
(Figure 22). FIG. 24 NOTE: FaST Model - - When using the FaST system, the solution flow control knob is nonfunctional. The FaST system has a set solution flow rate. Nobles Speed Scrub 17 - - 20 (03- -07)
NOTE: The Drive Model battery meter also displays machine fault codes. If a fault is detected the LED bars will flash specific fault codes (See BATTERY METER LED FAULT CODES on page 26). Nobles Speed Scrub 17 - - 20 (03- -07)
DRAINING RECOVERY TANK FIG. 31 1. Transport machine to disposal area and turn key switch off. 2. While holding the drain hose upward, remove the cap and lower hose to drain (Figure 29). Nobles Speed Scrub 17 - - 20 (03- -07)
NOTE: The machine will not operate once the battery profile is properly set for your battery type before charger is connected. charging. Failure to properly set will result in battery damage. Nobles Speed Scrub 17 - - 20 (03- -07)
Contact Service Center. 100% LED blinks Abnormal cycle. Safety timer exceeded the 18 Battery maintenance required or replace while the 50% and hour charging time. battery. 75% LED’s are off. Nobles Speed Scrub 17 - - 20 (03- -07)
NOTE: The machine will not operate once the battery charger is connected. FIG. 40 FIG. 38 ATTENTION: Do not disconnect the charger’s DC cord from the machine’s receptacle when the charger is operating. Arcing may result. If the Nobles Speed Scrub 17 - - 20 (03- -07)
Page 19
(Figure 47). edge (Figure 44). Rotate blade if worn. Remove any dried concentrate from the hose (See SQUEEGEE BLADE REPLACEMENT on connector by soaking it in warm water. page 21) Nobles Speed Scrub 17 - - 20 (03- -07)
Make sure the solution tank is empty before Battery Cables Before Servicing Machine. removing filter. FIG. 49 2. Clean the battery tops to prevent corrosion (See BATTERY MAINTENANCE on page 22). 3. Check for loose battery cable connections. Nobles Speed Scrub 17 - - 20 (03- -07)
(Figure 55). Rotate the front blade to a new wiping edge and return the retainer plate. Make sure the retainer plate tabs engage the blade slots. Reinstall the band then retighten the knobs. Retainer Plate FIG. 52 FIG. 55 Nobles Speed Scrub 17 - - 20 (03- -07)
1. Drain the solution tank and recovery tank of all the check valve after draining. To access the water. injector assembly remove the front shroud. 2. Empty the solution tank filter located under the machine (Figure 60). Nobles Speed Scrub 17 - - 20 (03- -07)
This step could take anywhere from 5--10 minutes. 10. When finished, connect the supply hose to the storage plug (Figure 64). FIG. 64 11. To drain the antifreeze from the FaST supply hose, repeat steps 5 and 6. Nobles Speed Scrub 17 - - 20 (03- -07)
Contact Service Center Faulty pump Contact Service Center Clogged solution tank filter Drain solution tank. remove solution tank filter, clean and reinstall Clogged orifice/filter screen Replace orifice/filter screen (See FaST SYSTEM MAINTENANCE) Nobles Speed Scrub 17 - - 20 (03- -07)
Transporting 8% (5°) * Run times are based on Continuous Scrubbing Run Times. ** Sound levels (ISO 11201) as recommended by the American Association of Cleaning Equipment Manufacturers (AACEM) and OSHA. Nobles Speed Scrub 17 - - 20 (03- -07)
(17 in / 43cm model) 21.5 in / 549 mm 50.25 in / 1276 mm (20 in / 50cm model) (20 in / 50 cm model) 30 in / 763 mm Nobles Speed Scrub 17 - - 20 (03- -07)