Phone: (800) 553- -8033 or (763) 513- -2850 www.nobles.com FaST--PAK is a registered United States trademark of Tennant Company. Specifications and parts are subject to change without notice. Copyright E 2006 TENNANT COMPANY, Printed in U.S.A. All rights reserved. Nobles Speed Scrub (08- -06)
Gas. Keep Sparks And Open Flame Away. Keep Battery Compartment Open When Charging. SPINNING BRUSH LABEL - - Located on scrub head WARNING: Spinning Brush. Keep Hands Away. Turn Off Power Before Working On Machine. Nobles Speed Scrub (08- -06)
8. Off--Aisle Wand on/off Switch (option) 3. Start Triggers 9. FaST System on/off Switch (option) 4. Brush Pressure Meter 10. Main Power on/off Key Switch 5. Control Console Height Adjustment Lever 11. Hour Meter 6. Speed Control Knob Nobles Speed Scrub (08- -06)
7.5 in / 190 mm W x 10.8 in / 275 mm L x 11.2 in / 284 mm H. 1. Park the machine on a level surface, remove the key and set the parking brake, if equipped. Nobles Speed Scrub (08- -06)
Stripping Pad (Brown) - - Used for stripping of floor finish to prepare the floor for recoating. Heavy Duty Stripping Pad (Black) - - Used for aggressive stripping of heavy finishes/sealers, or very heavy duty scrubbing. FIG. 5 Nobles Speed Scrub (08- -06)
2. Attach the pad to the pad driver before installing the driver. Secure pad with centerlock (Figure 8). FIG. 11 3. Attach idler plate to the brush end that has the double row of bristles (Figure 12). Install brush. FIG. 8 Nobles Speed Scrub (08- -06)
ATTENTION: For Conventional Scrubbing, only use commercially approved cleaning detergents. Machine damage due to improper detergent usage will void the manufacturer’s warranty. WARNING: Fire or Explosion Hazard. Never Use Flammable Liquids. FIG. 14 Nobles Speed Scrub (08- -06)
- Foam Scrubbing (FaST model): Make sure the solution tank is filled with cool clean water only. - Foam Scrubbing (FaST model): Ensure that all conventional cleaning agents are drained and rinsed from solution tank. FIG. 20 Nobles Speed Scrub (08- -06)
Page 13
NOTE: 148--197 feet / 45--60 meters per minute is the recommended scrubbing speed. 10. To stop scrubbing, release the triggers, raise the scrub head and squeegee and turn the key to the off position. FIG. 23 Nobles Speed Scrub (08- -06)
6. When leaving the machine unattended, remove the key and set the parking brake, if equipped. 7. If the machine detects a fault, the battery meter will blink a fault code (See BATTERY METER LED FAULT CODES). FIG. 28 Nobles Speed Scrub (08- -06)
7.5 A -- Off--aisle wand pump (located in control console) FIG. 30 3. Using the hose adapter, connect the squeegee hose to the wand hose (Figure 31). FIG. 29 FIG. 31 4. Attach the off--aisle wand to the hoses (Figure 32). FIG. 32 Nobles Speed Scrub (08- -06)
4. After scrubbing, turn off the wand switch and squeeze the trigger for five seconds to relieve the water pressure before disconnecting the solution hose. FIG. 38 WARNING: Fire or Explosion Hazard. Do Not Pick Up Flammable Materials Or Reactive Metals. Nobles Speed Scrub (08- -06)
The charger will display a sequence of codes. One of the codes will either read “GEL” or “Acd” (Figure 41). GEL = Set for sealed/maintenance free batteries Acd = Set for wet/lead acid batteries FIG. 41 Nobles Speed Scrub (08- -06)
If the charger detects a problem, the charger will display an error code (See ON--BOARD BATTERY CHARGER ERROR CODES). FIG. 43 5. Connect the charger’s AC power supply cord into a properly grounded receptacle (Figure 44). Nobles Speed Scrub (08- -06)
AC power supply cord first. FIG. 46 5. Connect the charger’s AC power supply cord into a properly grounded receptacle. 6. Connect the charger’s DC cord into the machine’s battery receptacle (Figure 47). Nobles Speed Scrub (08- -06)
6. Raise the scrub head and pull the machine away. 7. Observe the brush pattern on floor. If the brush pattern is uneven or tapered, adjustment is FIG. 49 required. 8. Reconnect drive motor wire. Nobles Speed Scrub (08- -06)
Page 21
3. Recheck brush pattern. NOTE: Replace brush when bristles are worn to 5/8 in / 15 mm. FIG. 56 5. Recheck brush pattern. NOTE: Replace brushes when bristles are worn to 5/8 in / 15 mm. Nobles Speed Scrub (08- -06)
FIG. 62 and clean (Figure 59). 7. Inspect the cylindrical brushes for wear. Rotate brushes from front--to--rear every 50 hours (Figure 63). Replace when worn to a length of 5/8 in / 15 mm. FIG. 59 Nobles Speed Scrub (08- -06)
Page 23
(Figure 68). FIG. 65 Cylindrical Brush Model Disk Model 10. Check the condition of the squeegee blade wiping FIG. 68 edge (Figure 66). Rotate blade if worn (See SQUEEGEE BLADES). Nobles Speed Scrub (08- -06)
(Figure 71). Make sure the solution tank is empty before removing filter. FIG. 74 6. Clean the parking brake clamp with a cleaning solvent. FIG. 71 7. Check the machine for loose nuts and bolts. Nobles Speed Scrub (08- -06)
2. Clean the batteries to prevent battery corrosion. Use a scrub brush with a mixture of baking soda and water (Figure 76). FIG. 78 FOR SAFETY: When cleaning batteries, wear protective gloves and eye protection. Avoid contact with battery acid. FIG. 76 Nobles Speed Scrub (08- -06)
11° ramp incline at a ramp length of 3.7m (12 ft), use tie- -down straps to secure machine and block machine wheels. FIG. 86 Nobles Speed Scrub (08- -06)
4. Operate the FaST system as normal until the foaming stops. This step could take anywhere from 5--10 minutes. 5. Remove the valve coupling and connect the storage plug (Figure 89). FIG. 89 6. Drain the recovery and solution tanks and store machine. Nobles Speed Scrub (08- -06)
Clean solution tank filter Discharged batteries Charge batteries Clogged solution valve Remove valve and clean Solution flow control knob set too low Adjust solution control flow knob Loose screw on control knob Calibrate knob and retighten screw. Nobles Speed Scrub (08- -06)
Page 30
Drain solution tank. Remove solution tank filter, clean and reinstall Clogged detergent orifice/filter screen Replace orifice/filter screen (See FaST SYSTEM MAINTENANCE) Clogged FaST solution inlet filter Contact Service Center FaST Pump fuse blown Replace 7.5A fuse Nobles Speed Scrub (08- -06)
GRADE LEVEL, MAX. Scrubbing 5% (3°), Transporting 8% (5°) * Run times are based on Continuous Scrubbing Run Times. ** Sound levels (ISO 11201) as recommended by the American Association of Cleaning Equipment Manufacturers (AACEM) and OSHA. Nobles Speed Scrub (08- -06)
28 in / 711 mm 34 in / 864 mm 35.7 in / 908 mm 41.3 in / 1,051 mm 46.6 in / 1,185 mm 41.3 in / 1,051 mm 46.6 in / 1,185 mm Nobles Speed Scrub (08- -06)