4.5.3 Tone Settings
BELL_CORE_PATTERN3_TIMING
Value Format
Description
Value Range
Default Value
BELL_CORE_PATTERN4_TIMING
Value Format
Description
Value Range
Default Value
BELL_CORE_PATTERN5_TIMING
Value Format
Description
Value Range
Default Value
RINGTONE_183_180_ENABLE
Value Format
Description
Value Range
Default Value
CONFIRM_TONE4_ENABLE
Value Format
Description
184
Administrator Guide
Comma-separated Integer
Specifies the cadence, in milliseconds, of pattern ID 3, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using 6 whole numbers separated by commas.
0–5000 (0: Infinite time)
400,200,400,200,800,4000
Comma-separated Integer
Specifies the cadence, in milliseconds, of pattern ID 4, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using 6 whole numbers separated by commas.
0–5000 (0: Infinite time)
300,200,1000,200,300,4000
Integer
Specifies the cadence, in milliseconds, of pattern ID 5, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14.
0–5000 (0: Infinite time)
500
Boolean
Specify whether to ring a local RBT when 180 is received after the early
media is established.
Y (Enable)
N (Disable)
N
Boolean
Specifies whether a notification tone is sent to participants when a
conference either begins or finishes.
Document Version
2013-02