Thelin Hearth Products, Inc. Tiburon Pellet Stove TIBURON PELLET STOVE Owner’s Manual SAFETY NOTICE STOVE MUST BE PROPERLY INSTALLED AND MAINTAINED OR A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW THE INSTALLATION INSTRUCTIONS. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION AND PERMIT.
Tiburon Pellet Stove Introduction Congratulations on your purchase of Thelin Hearth Products Tiburon pellet stove! In this manual you will find information on stove specifications, installation instructions, operating guide, how to perform scheduled maintenance, a troubleshooting guide, a detailed parts list and associated diagrams. Also included is your warranty information.
Page 5
Thelin Hearth Products, Inc. Tiburon Pellet Stove DO NOT overfire. If any external part starts to glow, you are over firing. Reduce feed rate. Overfiring or any such action that may cause a fire hazard including failure to perform regular maintenance as outlined in these instructions will void warranty.
The Tiburon pellet stove has been designed and approved for burning PREMIUM WOOD PELLETS OF HIGHEST BTU OUTPUT AND LOWEST % OF ASH CONTENT ONLY.
Page 8
Thelin Hearth Products, Inc. Tiburon Pellet Stove The stove may be installed as a free-standing unit mounted on a non-combustible protective floor pad or hearth. Non-combustible floor protection is required and must be used when placing the stove on any combustible material.
Thelin Hearth Products, Inc. Tiburon Pellet Stove Vent Information Install vent clearances as specified in this Owner’s Manual. USE TYPE L 3” OR 4” PELLET VENT PIPE DEPENDING ON YOUR INSTALLATION. Secure pipe adapter to rear flange with 500 degree HIGH-TEMP RTV silicone and using at least three sheet metal screws.
Page 11
Thelin Hearth Products, Inc. Tiburon Pellet Stove MOBILE HOME INSTALLATION Mobile home installation should be in accordance with the manufactured home and safety standard (HUD), CFR 3280, PART 24. 1. Outside combustion air is mandatory in mobile or modular home installations. An outside air inlet MUST be provided for combustion and ventilation air.
Installation Unpacking and Inspecting your Stove Thelin Hearth Products packages your stove to ensure safe delivery. Each stove is surrounded by impact absorbent material as well as load shift indicators. However, damage can still occur while the stove is in transit.
Page 13
Thelin Hearth Products, Inc. Tiburon Pellet Stove 6. A non-combustible hearth pad must be used if installed on a carpet, wood floor, or other combustible material (see FIGURE 3). Maintain 6” (152mm) beyond the front and beyond each side of the fuel loading and ash removal opening.
Page 14
Thelin Hearth Products, Inc. Tiburon Pellet Stove FIGURE 4 14 of 39...
Page 15
Thelin Hearth Products, Inc. Tiburon Pellet Stove FIGURE 5 15 of 39...
Page 16
Thelin Hearth Products, Inc. Tiburon Pellet Stove FIGURE 6 16 of 39...
Thelin Hearth Products, Inc. Tiburon Pellet Stove HORIZONTAL INSTALLATION WITH VERTICAL RISE 1. Hook up the pipe adapter to the rear exhaust flange of the stove, and silicone with 500 degree HIGH-TEMP RTV silicone. Screw together with at least three sheet metal screws. .
Thelin Hearth Products, Inc. Tiburon Pellet Stove FIGURE 7 VERTICAL INSTALLATION a. ALL VERTICAL RUNS REQUIRE 4” TYPE L PIPE. (FIGURE 4 and 5) b. Connect a vent tee with clean out cap and maintain a Minimum 3” clearance to combustibles.
¼” round pipe with air shutter located on the rear of the stove. Use a stainless hose clamp to attach flex pipe to the stove air intake flange. 4. Thelin Hearth Products recommends using a Dura Vent Wall Thimble Kit part # 60-0070-0003. Call your authorized Thelin Hearth Products dealer for this item.
Thelin Hearth Products, Inc. Tiburon Pellet Stove Operation Start-Up and Operation – CONTROL PANEL Open hopper lid and REMOVE all manuals and materials shipped with stove. Open front door and remove contents. Fill hopper with pellets. The Tiburon stove will hold approximately 50 pounds of pellets. The hopper lid must be closed before operating the unit.
Thelin Hearth Products, Inc. Tiburon Pellet Stove START UP AND OPERATION - HANDHELD REMOTE AND THERMOSTAT A wall thermostat or remote thermostat can be used to automatically control the Tiburon stove. The thermostat or handheld remote provides the option of turning the stove on and off.
Page 22
This will involve following Steps 7 through 10 to activate once again. BATTERY REPLACEMENT: Thelin Hearth Products recommends consideration be given to replacing all batteries at a minimum of every 6 months. There are batteries both in the handheld remote, and the black receiver located in the rear of the stove.
Page 23
Thelin Hearth Products, Inc. Tiburon Pellet Stove FIGURE 8 FIGURE 9 23 of 39...
Page 24
Thelin Hearth Products, Inc. Tiburon Pellet Stove FIGURE 10 FIGURE 11 24 of 39...
Thelin Hearth Products, Inc. Tiburon Pellet Stove Control Functions The push-button control settings on the Tiburon stove are as follows: OFF, FAN, LOW, MED, HIGH, and CLEAN (see FIGURE 12). FIGURE 12 1. In the LOW position, the Tiburon stove will feed approximately 2 pounds of pellets per hour. Feed rate will depend upon size of the pellets, quality of pellets and the feed trim setting.
Battery Light If you utilize the Thelin Hearth Products battery backup option, and the battery is plugged into the stove: The indicator light will come on blinking yellow when the battery is charging. The indicator light will come on steady yellow when the battery is fully charged.
Thelin Hearth Products, Inc. Tiburon Pellet Stove 7. The Battery Switch should be set to Internal Battery to start and maintain the trickle charge. NOTE: It is not recommended to leave stove unplugged, as the battery will lose its’ charge.
Page 28
Thelin Hearth Products, Inc. Tiburon Pellet Stove Run time on the battery will depend upon the amperage of the battery. See your local battery store for details. If you wish to place the battery beyond 4 ft from the stove you will need to increase the wire size of the cable.
Tiburon Pellet Stove Maintenance The Tiburon pellet stove requires routine maintenance for maximum performance and prolonged life of parts and components. Maintenance is mandatory for warranty to remain in effect. ALWAYS DISCONNECT POWER CORD BEFORE SERVICING. RISK OF ELECTRICAL SHOCK IF NOT DISCONNECTED.
Yearly Maintenance NOTE: THE FOLLOWING SHOULD ONLY BE PERFORMED BY SERVICE AND MAINTENANCE PERSONNEL FAMILIAR WITH BOTH PELLET STOVES AND IN PARTICULAR THELIN’S PRODUCT-LINE. WE RECOMMEND YOU CONSULT A THELIN HEARTH PRODUCT’S DEALER FOR A PROFESSIONAL SERVICE TECHNICIAN Soot and Fly Ash – The products of combustion will contain small particles of fly ash. The fly ash will collect in the exhaust venting system and restrict the flow of flue gasses.
Page 31
Thelin Hearth Products, Inc. Tiburon Pellet Stove Combustion blower fan 1. Make certain stove is unplugged from power outlet. 2. Stove may need to be removed from the Exhaust Vent and Outside Air Intake to access rear compartment. 3. Remove 6 screws on the Upper Rear Panel and remove Air Intake Flex Pipe from panel. Set panel aside.
Page 32
Thelin Hearth Products, Inc. Tiburon Pellet Stove HANDHELD REMOTE (if applicable) BATTERY REPLACEMENT: THP recommends consideration be given to replacing all batteries at a minimum of every 6 months. There are batteries both in the handheld remote, and the black receiver located at the rear of the stove.
Page 33
Thelin Hearth Products, Inc. Tiburon Pellet Stove FIGURE 13 33 of 39...
Contact your original installing dealer for warranty service. Check with your installing dealer in advance if they require you to pay a service call for any warranty work. Travel and shipping charges are not covered by this warranty. If the installing dealer is unable to provide parts or service, contact the nearest Thelin Hearth Products dealer located on our website.
Page 39
Thelin Hearth Products, Inc. Tiburon Pellet Stove THELIN HEARTH PRODUCTS 1312 Striker Avenue Suite 101 Sacramento, CA. 95834 39 of 39...
Need help?
Do you have a question about the TIBURON PELLET STOVE and is the answer not in the manual?
Questions and answers