Model SRK208CENF-L
Power source
1 Phase 220/240V 50Hz
Printed circuit board
Color symbol
Meaning of marks
Symbol
C
Capacitor for CM
C
CF
Capacitor for FM
I
CF
Capacitor for FM
O
CM
Compressor motor
F
Fuse
FM
Fan motor (Indoor unit)
I
FM
Fan motor (Outdoor unit)
O
Table of relay operations
Relay symbol
Control part
52C
; denotes magentized relay ×: denotes demagnetized relay
Notes (1)
(2) Th
is room temperature sensor. Th
1
BK
Black
BL
Blue
BR
Brown
RD
Red
OR
Orange
WH
White
Y/GN
Yellow/Green
Parts name
I
O
Operation
Cooling
CM
(the heat exchanger sensor) is frost prevention sensor. (for details, refer to pages 74)
2
Indoor unit
Wireless
R-Amp
Display
Symbol
LM
Louver motor
Th
,
Thermistor
1
2
Tr
Transformer
ZNR
Varistor
51C
Motor protector for CM
52C
Magnetic contactor for CM
Outdoor unit
Parts name
1-43