Model SRK56A (Indoor unit)
SRC56HA (Outdoor unit)
Item
Cooling capacity
(1)
Heating capacity
(1)
Power source
Cooling input
Running current (Cooling)
Heating input
Running current (Heating)
Inrush current
COP (In cooling)
Cooling
Noise level
Heating
Exterior dimensions
Height x Width x Depth
Color
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
(3)
Refrigerant
Refrigerant oil
Defrost control
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at High)
Air filter, Q'ty
Shock & vibration absorber
Operation control
Operation switch
Room temperature control
Pilot lamp
Safety equipment
O.D
Connecting method
Attached length of piping
Insulation
Drain hose
Power source cord
Connection
Size x Core number
wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
Heating
(2) The operation data are applied to the 220V, 230V or 240V districts respectively
(3) The refrigerant quantity to be charged includes the refrigerant in 7 m connecting piping. (Purging is not required even in the short piping.)
If the piping length is longer. (When it is 7 to 15 m, add 20 g refrigerant per meter.)
(4) When the unit is operated in cooling or dehumidification mode at the outside air temperature of 1ºC and less, there is a possibility that water leakage
occurs at the indoor unit.
Model
W
W
kW
A
kW
A
A
Sound level
Power level
dB
Sound level
Power level
mm
kg
kW
kg
R
W
(Cooling)
CMM
(Heating)
mm(in)
Item
Indoor air temperature
DB
27ºC
20ºC
SRK56A
1 Phase, 220/230/240V, 50Hz
Hi : 45
Lo : 38
Hi : 59
Lo : 52
Hi : 45
Lo : 38
Hi : 59
Lo : 52
298‚798‚203
Stucco white
10
Louver fins & grooved tubing
0.7 (BARREL FREEZE 32SAM)
Tangential fan x 1
23
11
13
Polypropylene net (washable) x 2
Wireless–Remote controller
MC. Thermostat
RUN (Green), TIMER (Yellow),
ECONO (Orange), HI POWER (Green)
Liquid line: ø6.35 (1/4") Gas line: ø12.7 (1/2")
Liquid line: 0.5m Gas line: 0.43m
Necessary (Both sides)
3m (3 cores with Earth)
1.5mm
Terminal block (Screw fixing type)
WB
DB
19ºC
35ºC
7ºC
SRC56HA
5000
6200
2.08
9.7/9.3/8.9
2.10
9.8/9.4/9.0
44/46/48
2.40
640‚850‚290
Stucco white
RM5526GNE4 (Rotary type) x 1
Line starting
Capillary tubes
R22 1.45
MC control
Propeller fan x 1
Cushion rubber (for compressor)
Dome mounted protector (for compressor)
Internal thermostat (for fan motor)
Flare connecting
Connectable
2
x 5 cores (With Earth)
Mounting kit
Outdoor air temperature
WB
24ºC
6ºC
51
65
53
67
45
1.9
35
39
39
Standards
ISO-T1, JIS C9612
ISO-T1, JIS C9612
1-11