Model SRK561CENF-L (Indoor unit)
SRC561CENF-L (Outdoor unit)
Item
Cooling capacity
(1)
Power source
Cooling input
Running current (Cooling)
Inrush current
COP (In cooling)
(5)
Noise level
Exterior dimensions
Height × Width × Depth
Color
Net weight
Refrigerant equipment
Compressor types & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
Refrigerant
(4)
Refrigerant oil
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at High)
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Pilot lamp
Safety equipment
O.D
Connecting method
Attached length of piping
Insulation
Drain hose
Power source cord
Size × Core number
Connection
wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
(2) The operation data are applied to the 220 V or 240 V districts respectively.
(3) Limitation of Voltage application
Minimum: 198 V
(4) The refrigerant quantity to be charged includes the refrigerant in 7.5 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, (when it is less than 10 m, add 10 g refrigerant per meter and when it is 10 to 15 m, add 30 g refrigerant per meter.)
(5) Expressed in sound pressure level.
1-18
Model
W
kW
A
A
dB (A)
mm
kg
kW
kg
R
W
CMM
Polypropylene net (washable) × 2
RUN (Green), TIMER (Yellow),
ECONO (Orange), HI POWER (Green)
mm (in)
Item
Indoor air temperature
DB
27°C
Maximum: 264 V
SRK561CENF-L
5000/5000
1 Phase, 220/240V, 50 Hz
2.08/2.18
10.2/9.53
44/48
2.40/2.29
45/45
275 × 790 × 189
Ivory white
9
Louver fins & tubing
Capillary tubes
R22 1.35
0.7 (BARREL FREEZE 32SAM)
Tangential fan × 1
23
12/12
Wireless-Remote controller
MC. Thermostat
Liquid line: φ6.35 (1/4") Gas line: φ12.7 (1/2")
Flare connecting
Liquid line: 0.4m
Gas line : 0.35m
Necessary (Both sides)
Connectable
2.5 m (3 cores with Earth)
× 3 cores (Including earth cable)
2
1.5 mm
Terminal block (Screw fixing type)
Mounting kit
Outdoor air temperature
WB
DB
19°C
35°C
SRC561CENF-L
53/54
615 × 850 × 290 + 30
Polar white
52
RM5526GNE4 (Rotary type) × 1
1.9
Line starting
Propeller fan × 1
40
34/34
Cushion rubber (for compressor)
Dome mounted protector (for compressor)
Internal thermostat (for fan motor)
Standards
WB
24°C
JIS C9612, ISO-T1

Hide quick links: