Model SRK50A (Indoor unit)
SRC50CA (Outdoor unit)
Item
(1)
Cooling capacity
Power source
Cooling input
Running current (Cooling)
Inrush current
COP (In cooling)
Sound level
Noise level
Power level
Exterior dimensions
Height × Width × Depth
Color
Net weight
Refrigerant equipment
Compressor types & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
(3)
Refrigerant
Refrigerant oil
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at High)
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Pilot lamp
Safety equipment
O.D
Connecting method
Attached length of piping
Insulation
Drain hose
Power source cord
Size × Core number
Connection
wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Item
Operation
Cooling
(2) The operation data are applied to the 220V, 230V or 240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 7 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, (When it is 7 to 15 m, add 20 g refrigerant per meter.)
(4) When the unit is operated in cooling or dehumidification mode at the outside air temperature of 1ºC and less, there is a possibility that water leakage
occurs at the indoor unit.
Model
SRK50A
W
kW
A
A
Hi : 44
dB
Hi : 58
mm
298 × 798 × 203
Noble white
kg
10
kW
kg
R
Tangential fan × 1
W
23
CMM
11
Polypropylene net (washable) × 2
Wireless-Remote controller
MC. Thermostat
RUN (Green), TIMER (Yellow),
ECONO (Orange), HI POWER (Green)
Liquid line: φ6.35 (1/4") Gas line: φ12.7 (1/2")
mm (in)
Liquid line: 0.5m
Gas line : 0.43m
Indoor air temperature
DB
WB
27°C
19°C
4500
1 Phase, 220/230/240V, 50 Hz
1.79
8.4/8.0/7.7
39/41/42
2.51
Lo : 37
Lo : 51
RM5523GNE4 (Rotary type) × 1
Louver fins & grooved tubing
Capillary tubes
R22 1.45
0.7 (BARREL FREEZE 32SAM)
Cushion rubber (for compressor)
Dome mounted protector (for compressor)
Internal thermostat (for fan motor)
Flare connecting
Necessary (Both sides)
Connectable
3 m (3 cores with Earth)
× 3 cores (Including earth cable)
1.5 mm
2
Terminal block (Screw fixing type)
Mounting kit
Outdoor air temperature
DB
WB
35°C
24°C
SRC50CA
51
65
640 × 850 × 290
Stucco white
44
1.7
Line starting
Propeller fan × 1
35
39
Standards
ISO-T1, JIS C9612