Advertisement

SASE
Bull 300 Vacuum Manual
SASE Company, Inc.
Phone 800.522.2606 or Fax 865.745.4110
www.SASECompany.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bull 300 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sase Bull 300

  • Page 1 SASE Bull 300 Vacuum Manual SASE Company, Inc. Phone 800.522.2606 or Fax 865.745.4110 www.SASECompany.com...
  • Page 2 SASE is able to provide unsurpassed service and technical support for the contractor. At SASE we engineer and manufacture our own equipment, which allows us to be in control of the quality of the equipment we sell. SASE offers a complete line of concrete preparation and polishing equipment, our newest introduction being our new line of PDG planetary diamond grinders, which is setting a new standard for the concrete grinding and polishing industry.
  • Page 3: Operating Instructions

    SASE BULL 300 Series Vacuum System Operating Instructions Instructions for Installation, Repair, and Maintenance CONTENTS Part 1: Health and Safety Part 2: Filter Maintenance Part 3: Ametek Motor...
  • Page 4 FOREWORD o achieve the safe installation and operation of your new BULL 300 vacuum system, we urge you to become familiar with the information in this manual. The SASE BULL 300 industrial vacuum cleaning system is designed for heavy duty operation. The mechanical and electrical components are of a robust nature and will provide long life with minimal maintenance even under severe conditions.
  • Page 5: Warranty

    Please note! The vacuum producer requires unrestricted air flow! Running the BULL 300 “deadheaded” for more than a few minutes will overheat the vacuum producer and void the warranty. This warranty shall be void if the equipment has been altered or if any attempt to repair this equipment has been made by persons, institutions or firms not authorized by SASE to make repairs.
  • Page 6: Health And Safety

    BEFORE OPERATING OR SERVICING THIS EQUIPMENT . his section outlines s ome of the health and safety issues that must be acknowledged when operating or servicing your SASE industrial vacuum cleaning system. It is important that plant operators are made aware of the responsibility...
  • Page 7 If your process is to be changed, or if you have any concerns, we suggest you contact us to see how we can assist you to ensure that the operation of your industrial vacuum cleaning system is as safe as possible. SASE Isolate Electrical Before Maintenance Company speci c...
  • Page 8 Use CAUTION When Using the Hoses vacuum systems use blowers that develop very high vacuum conditions SASE which can be dangerous if caution is not observed. DO NOT PUT THE END OF THE HOSE AGAINST YOUR...
  • Page 9: Maintenance Instructions

    Please read and follow the instructions on the following pages to ensure proper operation of each of the components of your system. The Filtration System The SASE BULL 300 Series of vacuum systems is designed to handle super-fine powders, so the filtration sub-system is its “heart” and must be maintained properly.
  • Page 10: Maintenance

    NOTE: A loose or unsecured bag will allow product to pass through the lter separator and will plug t he in-line lter. The lter bags should be shaken at least daily, preferably after each use. To shake filter bags, simply shut off the vacuum and shake the filter assembly arm swiftly back and forth.
  • Page 11 The Inline Filter The inline lter supplied with this unit will help prevent damage to the exhauster in case of failure of a primary filter bags. BULL 300 Should the air ow of the become reduced, check that the inline lter has not become blinded by dust, by removing the vacuum motor housing.
  • Page 12 PLEASE NOTE! The vacuum producer requires unrestricted air flow! Running the BULL 300 “deadheaded” for more than a few minutes will overheat the vacuum producer and void the warranty. THIS UNIT IS NOT RECOMMENDED FOR CONNECTION TO A CENTRAL VACUUM PIPING NETWORK.
  • Page 13 Vacuum Seals If you experience a “lack of suction”, almost certainly there is a leak in a seal somewhere in the system. The following is a short list of common fail points: Check all gasket seals. If air is leaking in through these seals, dust will normally collect on the inside surface of the housing showing the exact location of the leak.
  • Page 14 Product Bulletin LAMB ELECTRIC Model: 121118-00 SPECIAL FEATURES - "Generation II" (DIGITAL) Controller: no external low-voltage control power DESCRIPTION required. (See "INFIN-A-TEK - Brushless Motor Application Notes") - Switch Reluctance (SR) Technology - UL component recognized (pending) - One-stage High Flow Fan design - IP Rating: 1.0 - 120 volts, 50/60 Hz - Speed control capability...
  • Page 15 PRODUCT BULLETIN 121118-00 DIMENSIONS NOTES 1. Leads: 18ga, stranded power leads; one black and one white, ground lead green with yellow stripe. Leads: 22ga, control leads: one red, one blue (or orange) and one yellow. 2. Motor Identification: Manufacturer's name, model number, voltage, frequency, inspection code, date of manufacture, agency recognition code, plant code, "Thermally Protected L 16.0A", "Made in the USA"...
  • Page 16 SASE BULL 300 BLOWER 28.38 FILTER SHAKER SOUND PROOFING SAFETY FILTER 36.7 SF PRIMARY FILTER HEAVY DUTY FRAME 3" OD 5" SASE COMPANY, INC. KENT, WA 98032 800-522-2606...

Table of Contents