Physical Data; Accessories - Carrier 38TDB Product Data

(60 hz) two-speed air conditioner with puron refrigerant
Hide thumbs Also See for 38TDB:
Table of Contents

Advertisement

Physical data

UNIT SIZE - SERIES
OPERATING WEIGHT (Lb)
REFRIGERANT
Cooling Control
Charge (Lb)
CONDENSER FAN
Air Discharge
Air Qty (CFM)
Motor HP
Motor RPM
CONDENSER COIL
Face Area (Sq Ft)
Fins per in.
Rows
Circuits
VALVE CONNECT. (In. ID)
Vapor
Liquid
REFRIG TUBES* (In. OD)
Vapor
Liquid
LONG LINE REFRIGERANT TUBES (In. OD)
Vapor
Liquid
NOTE: See unit installation instructions for proper installation.
* Tube sizes are for runs up to 50 ft horizontal and/or 20 ft vertical differential. Standard long line–up to 175 ft.
†High speed

Accessories

ORDERING NO.
KAACF0801MED
KSASF0101AAA
KSATX0201PUR
KSATX0301PUR
KSATX0401PUR
KSATX0501PUR
THERMOSTAT
TSTATCCPRH01-B
TSTATCCP2S01-B
TSTATCCN2S01-B
TSTATXXSEN01-B
TSTATXXNBP01
TSTATXXPBP01
TSTATXXCNV10
INFINITY™* CONTROLS
SYSTXCCUID01
SYSTXCCUIZ01
SYSTXCC4ZC01
SYSTXCCSMS01
SYSTXCCRRS01
SYSTXCCSAM01
SYSTXCCNIM01‡‡
SYSTXXXBPU01
* When applied with Carrier's IdealHumidity™ series 58MVP, 58CV(A,X) and FE Indoor Models.
‡‡Must be installed in Dual-Fuel Infinity system applications.
024-30
171
6.0
1500
1/15
825
10.8
25
1
2/1
5/8
5/8
3/4
Coastal Filter — Sizes 024-060
Support Feet (4)
Bi-flow Balance Port TXV (Hard Shut Off)-Size 024
Bi-flow Balance Port TXV (Hard Shut Off)-Size 036
Bi-flow Balance Port TXV (Hard Shut Off)-Size 048
Bi-flow Balance Port TXV (Hard Shut Off)-Size 060
Carrier Thermidistat™ Control — Non-Programmable/Programmable Thermostat with Humidity Control
(For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.)
Carrier Thermostat, Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat/2-Stage Cool in AC
Mode, 3-Stage Heat/2-Stage Cool in HP mode
Carrier Thermostat, Auto Changeover, Non-Programmable, °F/°C, 2-Stage Heat/2-Stage Cool in AC
Mode, 3-Stage Heat/2-Stage Cool in HP mode
Outdoor Temperature Sensor
Backplate for Non-Programmable Thermostat
Backplate for Programmable Thermostat
Thermostat Conversion Kit (4 to 5 Wire) — 10 Pack
Infinity Control Deluxe 7-Day Programmable (Wall-mounted system control.)
Infinity Control Deluxe Zoning 7-Day Programmable (Wall-mounted control for a multi-zone system.)
Z
O
Infinity 4-Zone Damper Control Module (Wall-mounted control for a four-zone system.)
N
Infinity Smart Sensor (Optional wall control used to monitor temperature and/or fan control in an
I
individual zone.)
N
G
Infinity Remote Room Sensor (Monitors temperature in an individual zone.)
Infinity System Access Module (Hardware for wireless access and control via phone or internet.)
Infinity Network Interface Module (Connects Heat Recovery and Energy Recovery Ventilators or older two-
speed outdoor models to system.)
Decorative Back Plate for Infinity Control (Decorative wall plate.)
036-30
037-30
228
276
Puron® (R-410A)
TXV
8.9
12.3
Propeller Type, Direct Drive
Vertical
2500
2750†
1/8
1/5
825
840†
Copper Tube, Aluminum Plate Fin
18.2
18.2
25
20
1
2
3/1
4/1
Sweat
3/4
7/8
3/8
3/4
7/8
3/8
7/8
7/8
3/8
DESCRIPTION
DESCRIPTION
DESCRIPTION
048-30
060-31
266
311
11.5
13.1
3000
3100
1/5
1/5
825
825
18.2
18.2
20
20
2
2
5/1
5/1
7/8
7/8
7/8
1-1/8
7/8
1-1/8
3