Carrier 38TZA Product Data

Carrier 38TZA Product Data

(60 hz) air conditioner with puron (r-410a), sizes 024 thru 060
Hide thumbs Also See for 38TZA:

Advertisement

Copyright 1999 Carrier Corporation
Product
Data
38TZA (60 Hz)
Air Conditioner
with Puron
(R-410A)
®
Sizes 024 thru 060
Carrier's WeatherMaker 38TZA with
Puron® provides a completely unique
collection of features which cannot be
matched by any other family of
equipment. The 38TZA family has been
designed as the first air conditioning
system utilizing Carrier's unique Puron®
refrigerant. The environmentally sound
refrigerant allows you to make a
responsible decision in the protection of
the earth's ozone layer. Carrier's
WeatherMaker systems with Puron®
meet the Energy Star® guidelines for
energy efficiency.

AVAILABLE OPTIONS

WeatherArmor™ III System— The
casing steel is galvanized and coated with
a layer of zinc phosphate. A modified
polyester powder coating is then applied
and baked on, providing each unit with
a hard, smooth finish that will last for
many years.
All screws on the cabinet exterior are
SermaGuard™ coated for a long lasting,
rust-resistant, quality appearance.
The coil is protected by an enhanced
WeatherArmor™ heavy duty inlet grille.
Constructed of a coated 12 gage steel wire
grid and with spacing of 3/8 in., the guard
helps to protect the coil from inclement
weather, vandalism, and incidental
damage. It provides protection while not
restricting airflow and maintaining ease of
coil inspection and cleaning.
Puron® Environmentally Friendly
Refrigerant — Is Carrier's unique
refrigerant designed to help protect the
environment. Puron® is an HFC
refrigerant which does not contain
chlorine that is damaging to the ozone
layer. The most important advantage of
Puron® refrigerant is that it has not been
banned in future air conditioning systems
as the traditional refrigerant, R-22, has
been. Puron® refrigerant is in service in
thousands of systems providing highly
reliable, environmentally sound
performance. For specific R-22 phase out
information see your Carrier distributor.
High Efficiency Performance — Is
delivered through a combination of
features including Carrier's Puron®
refrigerant, unique scroll compressor, and
advanced heat transfer surfaces. Efficiency
ratings are 12 SEER (Seasonal Energy
Form 38TZA-3PD

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 38TZA

  • Page 1: Available Options

    Carrier’s WeatherMaker 38TZA with Puron® provides a completely unique collection of features which cannot be matched by any other family of equipment. The 38TZA family has been designed as the first air conditioning system utilizing Carrier’s unique Puron® refrigerant. The environmentally sound...
  • Page 2: Model Number Nomenclature

    Carrier family in its last 3 protection in the compressor including a total of 10 years. A five year warranty is years of service.
  • Page 3: Physical Data

    Physical data 024-30, 32 030-30, 32 036-30, 32 042-30, 32 048-30, 32 060-30, 32 UNIT SIZE-SERIES Operating Weight (Lb) COMPRESSOR Manufacturer Copeland Type Scroll REFRIGERANT Puron® (R-410A) Control AccuRater® (Bypass Type) Charge (Lb) 5.31 5.19 5.43 5.43 5.75 8.00 COND FAN Propeller Type, Direct Drive Air Discharge Vertical...
  • Page 4 Accessories ORDERING NO. DESCRIPTION KAATD0101TDR Time-Delay Relay — All Sizes KSALA0301410 Low-Ambient Pressure Switch — All Sizes P251-0083 (RCD) Low-Ambient Controller — All Sizes 32LT660004* (RCD) MotorMaster® Control — All Sizes KAAFT0101AAA† Evaporator Freeze Thermostat — All Sizes KAAWS0101AAA† Winter Start Control — All Sizes KSACY0101AAA Cycle Protector —...
  • Page 5 Accessory description and usage (Listed alphabetically) 1. Ball Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. SUGGESTED USE: Required on all units where Low-Ambient Controller (full modulation feature) or MotorMaster® Control has been added. 2.
  • Page 6: Electrical Data

    Electrical data 60°C 75°C 60°C 75°C FUSE** OR OPER VOLTS* COMPR UNIT SIZE- WIRE WIRE LENGTH LENGTH CKT BKR SIZE† SIZE† (Ft)‡ (Ft)‡ AMPS SERIES V/PH 024-30, 32 61.0 13.5 17.4 030-30, 32 72.5 14.7 19.2 036-30, 32 83.0 15.4 20.1 208/230/1 042-30, 32...
  • Page 7 Dimensions...
  • Page 8: Combination Ratings

    Combination ratings SEER FACTORY- SUPPLIED Carrier Gas Furnace UNIT INDOOR TOT. CAP. ENHANCE- Standard or Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† TXV‡ CK5A/CK5BA030* 23,200 NONE — 12.00 12.00 10.30 CC5A/CD5AA024 23,000 NONE — 11.70 11.70 10.15 CC5A/CD5AA030 23,200 NONE —...
  • Page 9: Combination Ratings Continued

    Combination ratings continued SEER FACTORY- SUPPLIED Carrier Gas Furnace UNIT INDOOR TOT. CAP. ENHANCE- Standard or Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† TXV‡ FX4ANF030 27,800 TDR & TXV 12.00 — 12.00 10.60 FX4ANF036 28,000 TDR & TXV 12.00 —...
  • Page 10 Combination ratings continued SEER FACTORY- SUPPLIED Carrier Gas Furnace UNIT INDOOR TOT. CAP. ENHANCE- Standard or Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† TXV‡ FV4ANB006 35,800 TDR & TXV 14.00 — 14.00 12.25 FV4ANF002 34,000 TDR & TXV 12.60 —...
  • Page 11 Combination ratings continued SEER FACTORY- SUPPLIED Carrier Gas Furnace UNIT INDOOR TOT. CAP. ENHANCE- Standard or Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† TXV‡ F(A,B)4AN(F,B,C)042 39,500 11.70 — 11.70 10.05 F(A,B)4AN(F,B,C)048 40,000 12.00 — 12.00 10.25 FC4BN(F,B)042** 38,500 TDR & TXV 11.50...
  • Page 12 Combination ratings continued SEER FACTORY- SUPPLIED Carrier Gas Furnace UNIT INDOOR TOT. CAP. ENHANCE- Standard or Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† TXV‡ CK3BA048 45,000 NONE — 11.70 11.70 10.20 CK3BA060 46,000 NONE — 12.00 12.00 10.40 CK5A/CK5BA048...
  • Page 13 † In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in perfor- mance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Carrier furnaces are equipped with TDR.
  • Page 14: Detailed Cooling Capacities

    Detailed cooling capacities* CONDENSER ENTERING AIR TEMPERATURES °F EVAP Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡...
  • Page 15 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡...
  • Page 16 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡...
  • Page 17 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡...
  • Page 18 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡...
  • Page 19 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡...
  • Page 20: Condenser Only Ratings

    Condenser only ratings* CONDENSER ENTERING AIR TEMPERATURES °F °F 38TZA024-30, 32 23.5 22.2 20.9 19.6 18.3 17.0 15.6 14.2 74.0 83.8 93.5 103.0 113.0 123.0 132.0 142.0 1.17 1.33 1.52 1.72 1.93 2.16 2.40 2.67 25.8 24.4 23.0 21.5 20.1 18.6 17.2 15.6...
  • Page 21 Condenser only ratings* continued CONDENSER ENTERING AIR TEMPERATURES °F °F 38TZA042-30, 32 37.4 35.4 33.3 31.3 29.2 27.1 25.0 22.6 74.9 84.4 94.0 104.0 113.0 123.0 132.0 141.0 1.94 2.21 2.51 2.84 3.22 3.63 4.08 4.58 41.0 38.8 36.6 34.3 32.1 29.8 27.4...
  • Page 22 System design summary 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc. 2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C). 3. Maximum outdoor operating air temperature is 125°F (51.7°C). 4.
  • Page 23: Typical Installation

    Typical installation AIR CONDITIONER COMFORT VENTILATOR™ COMFORT ZONE™ II EQUIPMENT CONTROLLER HUMIDIFIER FURNACE COIL FURNACE AIR CLEANER A98600...
  • Page 24: Guide Specifications

    Indianapolis, IN 46231 11-99 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book Page 24 Catalog No. 523-787 Printed in U.S.A. PC 101 Form 38TZ -3PD Replaces: 38TZA-2PD 3a 2a...