JVC VN-C20 Instructions Manual page 37

Box type
Hide thumbs Also See for VN-C20:
Table of Contents

Advertisement

A
Action
B
1st Trigger
C
Max.Interval
D
2nd Trigger
For specifying the type of action.
Disable
: Zero activation.
Mail
: Send via e-mail. Specify the recipient's mail address. The
title of the mail will appear as [Alarm from VN-C20] and the
sender as [Camera ID].
Enter the message to send in [Mail Text]. Input of up to 127
alphanumeric characters is allowed. To attach the latest
image to the mail, set image attachment to AOnB.
FTP
: Send pre-/post-recorded JPEG files via FTP.See Page for
details on pre-/post-recording and FTP server settings.
(A Page 39)
The maximum transmission rate of FTP is 1 Mbps.If a new
FTP trigger occurs during post-recording, the recorded
portion is treated as pre-recording and a new post-
recording starts.During FTP transmission after finishing
the post-recording, a new post-recording starts if a new
FTP trigger occurs.
TCP
: Send the character string entered in the [TCP/UDP Date]
field to the destinations specified in [TCP/UDP IP Address]
and [TCP/UDP Port Number] via TCP.
UDP
: Send the character string entered in the [TCP/UDP Date]
field to the destinations specified in [TCP/UDP IP Address]
and [TCP/UDP Port Number] via UDP.
TCP/UDP Date
: Input of up to 127 alphanumeric characters.
Output 1 Make
: Change Alarm Output 1 to Make.
Output 2 Make
: Change Alarm Output 2 to Make.
Output 1 Break
: Change Alarm Output 1 to Break.
Output 2 Break
: Change Alarm Output 2 to Break.
Specifies the first trigger to be activated.
Either alarm input (make), alarm input (break) or motion detection can be
selected.
Note:
● When the second trigger is turned off, only the first trigger will be
activated.
● When motion detection is selected as the first trigger, selection of
AMax.IntervalB and A2nd TriggerB will be disabled.
Valid only when first and second triggers have been specified.
It dictates (determines) the maximum interval between the first and second
triggers. Activation will take place only if the interval between first and
second triggers is less than the maximum interval.
Specifies the second trigger to be activated.
Either alarm input (make) or alarm input (break) can be selected. Unlike the
first trigger, motion detection is not available as a choice.
Set the alarm output time in the [Alarm Output Duration]
field.
37