Set" Function - Adjustments; Purg" Function - Purge; Info" Function - Information; Troubleshooting - Junkers SUPRAECO W HP 270 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Upon reaching a temperature of 70 °C, the device returns to the
previously selected mode.
The disinfection process will not be repeated until it is
reactivated.
8.5.4 „Set" function - adjustments
The „Set" function permits adjustment of the following values:
• Temperature units (
Chapter 8.8)
• Time and day of the week (
Fig. 37 „Set" function
8.5.5 „Purg" function - purge
„Purg" function is an auxiliary for the system purging process.
Fig. 38 „Purg" function
To activate „Purg" function
B Access „Purg" function and press „OK".
B Circulation pump will start functioning. After 5 minutes the appliance
returns to the operating mode previously selected.
8.5.6 „Info" function - information
The „Info" function permits display of the cumulative consumption over
the past 30 days.
Fig. 39 „Info" function
Displaying the consumption
B Access the „Info" function and press „ok".
Displays cumulative consumption (in kWh).
SUPRAECO W – 6 720 646 161 (2012/04)
Chapter 8.9).
6720646160-18.1V
6720801967 02 1V
6720646160-36.1V
„reset" consumption
Displays with indication of cumulative consumption.
B Press „-".
Displays with blinking „del" indication.
Fig. 40 „del" function
B Press „ok".
The meter restarts the count.
8.6

Troubleshooting

This device is equipped with a troubleshooting function. Anomaly
indication is performed by means of a code (Table 10, page 28)
corresponding to the error indication symbol in the digital visor (Fig. 18,
[6]) and the blinking of the functioning indicator light. In most cases, the
device will only return to normal functioning following elimination of the
cause of the malfunction and resetting of the device.
To identify the malfunction, see Chapter 11.
-
menu
Fig. 41 Error code
Resetting the system
B Press the „ok" key and hold it down for over 3 seconds.
-
menu
> 3 s
Fig. 42 Resetting the system
Operation
6720646160-42.1V
+
ok
6720646160-43.1V
+
ok
6720646160-21.1V
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents