Main" Menu; Mode" Function - Heating Modes - Junkers SUPRAECO W HP 270 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Operation
B Press the „+" or „-" keys until the desired value is reached.
Fig. 23 Setting the temperature
B Press the „ok" key to confirm the selection.
The selected temperature will blink 3x to signal confirmation.
The selected value blinks until the selection is validated.
If the selection is not validated within 10 seconds, the
previously selected value will remain active.
8.5

„Main" menu

Accessing the „Main" menu
B Press the „menu" key and hold it down for over 3 secs.
menu
> 3 s
Fig. 24 Accessing the „Main" menu
Accessing the „Main" menu provides access to the following functions:
• Mode - „Heating modes"
• Prog - „Timetable operation programming"
• Leg - „thermal disinfection"
• Set - „adjustments"
• Purg - „purge"
• Info - „information"
B Use the „+" or „-" keys to select the desired menu.
B Confirm using the „ok" key
8.5.1 „Mode" function - heating modes
The „Mode" function permits selection of 3 different heating modes:
• „Electrical" mode
• „Heat pump" mode
• „Combi" mode
20
6720646160-13.1V
-
+
ok
6720646160-49.1V
Fig. 25 „Mode" function
„Electrical" mode
In this mode, the only heat source used is electrical power.
Fig. 26 „Electrical" mode
This mode permits setting the water temperature anywhere between
30 °C and 70 °C.
„Heat pump" mode
Water heating is only assured while air inlet is between
5 °C and 35 °C.
Fig. 27 „Heat pump" mode
This mode permits setting the water temperature anywhere between
30 °C and 60 °C.
Very low temperatures trigger activation of the „anti
freeze" protection function (
„Combi" mode
This mode used two heat sources, depending on conditions: the heat
pump or the electrical supply.
6720646160-19.1V
6720646160-07.1V
6720646160-06.1V
page 19).
SUPRAECO W – 6 720 646 161 (2012/04)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents