6.5 Control pressure switch for water level in the tub

Control of the water level is performed by a three-level pressure switch which functions as follows:
contact 11-14: anti-boiling safety level
contact 21-24: first level
contact 31-32: anti-overflow safety level (some models may not feature it)
6.5.1

Pressure switch settings

Anti-boiling level
1st level
Anti-overflow level
6.5.2

Water fill without wash load

The table below shows the average water fill to reach the anti-boiling level and the first level without wash
load: data are gathered with empty drain circuit (if the drain circuit has not been emptied the water quantity
is reduced by about 0,7 litres).
Anti-boiling level (litres)
1st level (litres)
SOI/DT 2002-07 eb
Full (mm)
Refill (mm)
55± 3
35± 3
75± 3
55± 3
390± 15
240±50
G19 tub
3,5 (3,4÷3,7)
5,6 (5,4÷6)
30
599 35 36-69