4.2.41 User group selection (Pr. 160, Pr. 173 to Pr. 176)

Pr. 160 "user group read selection"
Pr. 173 "user group 1 registration"
Pr. 174 "user group 1 deletion"
Pr. 175 "user group 2 registration"
Pr. 176 "user group 2 deletion"
Among all parameters, a total of 32 parameters can be registered to two different user
groups. The registered parameters may only be accessed.
The other parameters cannot be read.
Parameter
Factory
Number
Setting
160
173
174
175
176
<Setting example show the use of the control panel (FR-PA02
( 1 ) Registration of parameter to user group ( when registering Pr. 3 to
user group 1 )
Pr. 173 reading
SET
The number of
parameters set and
registered by the
user appears.
(2) Deletion of parameter from the user group (when Pr. 5 is deleted
from user group 1)
Pr. 174 reading
SET
The number of
parameters set and
registered by the
user appears.
Setting Range
0
0, 1, 10, 11
0
0 to 999
0
0 to 999, 9999
0
0 to 999
0
0 to 999, 9999
Press the
key to select the
parameter number to
be registered.
Press the
key to select the
parameter number to
be deleted.
146
Remarks
9999: Batch deletion
9999: Batch deletion
Flickering
SET
1.5s
/
Pr. 3 is registered
to user group 1.
Flickering
SET
1.5s
Pr. 5 is deleted
/
from user group 1.
PARAMETERS
)>
-02
Press the
/
key to shift to the next
parameter to be
registered.
Press the
key to
SET
register the parameter.
Press the
/
key to shift to the next
parameter to be
deleted.
Press the
key to
SET
delete the parameter.
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents