Alarm I/O Pin Configuration - Eneo GLS-2301H Installation And Operating Manual

Network 1-channel video/audio server, mjpeg, h.264, ethernet
Table of Contents

Advertisement

3.3 ALARM I/O PIN Configuration

1.
RS-485 pin: D+
2.
RS-485 pin: D–
3.
GND1: Ground Contact
4.
ALARM RESET (INPUT): This pin connects to an alarm-clear device for clearing an alarm (
5.
GND2: Ground Contact
6.
ALARM IN 1 (INPUT): This is an alarm input which can be programmed in the menu system to Normally Open
or Normally Closed (
7.
ALARM IN 2 (INPUT): This is an alarm input which can be programmed in the menu system to Normally Open
or Normally Closed (
8.
ALARM IN 3 (INPUT): This is an alarm input which can be programmed in the menu system to Normally Open
or Normally Closed (
9.
ALARM IN 4 (INPUT): This is an alarm input which can be programmed in the menu system to Normally Open
or Normally Closed (
10. ALARM IN 5 (INPUT): This is an alarm input which can be programmed in the menu system to Normally Open
or Normally Closed (
11. ALARM IN 6 (INPUT): This is an alarm input which can be programmed in the menu system to Normally Open
or Normally Closed (
12. GND3: Ground Contact
13. AUDIO IN Connector: The connector is used to connect the audio output from a camera or other devices.
14. AUDIO OUT Connector: The connector provides the unit's audio signal to a speaker or stereo.
15. GND4: Ground Contact
16. ALARM OUT 1 (OUTPUT): This is an alarm-output trigger. Connect this to external devices such as buzzers or
lights (
5V
0V(Active)
17. ALARM OUT 2 (OUTPUT): This is an alarm-output trigger. Connect this to external devices such as buzzers or
lights (
5V
0V(Active)
18. ALARM OUT 3 (OUTPUT): This is an alarm-output trigger. Connect this to external devices such as buzzers or
lights (
5V
0V(Active)
19. ALARM OUT 4 (OUTPUT): This is an alarm-output trigger. Connect this to external devices such as buzzers or
lights (
5V
0V(Active)
20. ALARM OUT 5 (OUTPUT): This is an alarm-output trigger. Connect this to external devices such as buzzers or
lights (
5V
0V(Active)
21. ALARM OUT 6 (OUTPUT): This is an alarm-output trigger. Connect this to external devices such as buzzers or
lights (
5V
0V(Active)
22. GND5: Ground Contact
23. DC-OUT: DC-V 350mA max.
24. GND6: Ground Contact
5V
).
0V(Active)
5V
).
0V(Active)
).
5V
0V(Active)
5V
).
0V(Active)
5V
).
0V(Active)
5V
).
0V(Active)
).
).
).
).
).
).
7
5V
).
0V(Active)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gls-2202h

Table of Contents