7.10. Remove the Stand brackets
1. Remove the Plasma panel section from the servicing
stand and lay on a fiat surface such as a table (covered)
with the Plasma panel surface facing downward.
2. Remove the Stand brackets (L, R) fastening screws (×4
each) and remove the Stand brackets (L, R).
7.11. Remove the C1-Board
1. Remove the A-Board unit. (See section 7.4.)
2. Remove the Stand bracket L. (See section 7.10.)
3. Remove the flexible cables holder fastening screws (×8
).
4. Disconnect the flexible cables (CB1, CB2, CB3 and CB4).
5. Disconnect the flexible cables (C10 and C11).
6. Remove the screws (×4
7.12. Remove the C2-Board
1. Remove the A-Board unit. (See section 7.4.)
2. Remove the stand bracket R. (See section 7.10.)
3. Remove the flexible cables holder fastening screws (×8
).
4. Disconnect the flexible cables (CB5, CB6, CB7 and CB8).
5. Disconnect the flexible cables (C20 and C21).
6. Disconnect the connector (C23).
7. Remove the screws (×4
7.13. Remove the Front bracket
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (A51 and A52). (See section
7.4.)
3. Remove the screws (×2
Front bracket.
19
) and remove the C1-Board.
) and remove the C2-Board.
, ×2
) and remove the