Digitech ENU rev. Feb 2011 Contents Haglöf Sweden® ..............................5 Mantax Digitech® ..............................6 Assemble the caliper jaws ............................7 Adjust the handle ............................... 8 Jaw angle ................................8 MENU SELECTIONS ..............................9 Battery ................................10 LOCAL ................................10 1-key registration (1But) ..........................10 3-key registration ............................
Page 3
Digitech ENU rev. Feb 2011 PC ..................................13 DigiCom V1.0 ................................. 14 Code .................................. 14 Name of tree species ............................15 Edit Data ................................15 Delete 0-diameters ............................15 Two 0-diameters=New plot ..........................15 Three 0-diameters=New List, Stand ......................... 15 Export data ...............................
Digitech ENU rev. Feb 2011 HAGLÖF SWEDEN® HAGLÖF SWEDEN AB IS A FAMILY OWNED COMPANY WITH A LONG TRADITION OF DEVELOPING AND PRODUCING INSTRUMENTS FOR PROFESSIONAL FOREST MEASURING WORK. TODAY, HAGLÖF SWEDEN MANUFACTURE AND SELL THE MOST COMPLETE PRODUCT RANGE FOR CRUISING AND INVENTORY WORK.
The E-key - Enter is used to activate the function you have chosen to work with. E is also used to turn on the Digitech caliper. To turn off, simply press both arrow keys simultaneously (ESC) when caliper is set in main menu.
Digitech ENU rev. Feb 2011 ASSEMBLE THE CALIPER JAWS Assemble the caliper jaws using the enclosed Allen key (wrench) and the screws with washers. Make sure the jaws are correctly assembled and guided into the material marks on your caliper.
Digitech ENU rev. Feb 2011 ADJUST THE HANDLE In the back part of the caliper handle you will find a compartment containing a small Allen key. Use the Allen key to adjust the sliders and jaw angle for perfect run and alignment.
Digitech ENU rev. Feb 2011 MENU SELECTIONS LOCAL LINE INSP PRNT COPY RAND Measured Measured Delete trees Show Transfer Send stand Transfer Set random Set 1-key or 3- trees are trees sent with measured table to HP measured and memory...
The number of captured measurements is featured in the display for a short while. Registration of tree species and diameters can be made in two different ways, and your choice is made under SET in the menu. When delivered, the Digitech caliper is set in 3-key registration mode. 1-KEY REGISTRATION (1BUT) Press the caliper jaws around the object to measure a diameter.
(turn to the instruments manual for details on measuring result transmission). Repeat the process if necessary (for example if the Digitech caliper did not respond to the IR transfer). NOTE: It is important to aim the IR exit port on the instrument towards the IR input on the Digitech to transfer data.
CR=carrige return character, LF=Line feed character. Note: The caliper Id can be set in the Digitech® menu Set. If the Id is 1, 2, 3, 4, 5 or 6, an extra digit is added after the diameter digits. This makes it possible for a receiving unit (handheld computer) to separate caliper data if more than one caliper unit is operating in the field transferring online measuring results.
(=tree) can be registered, normally stating the total height, the height of green crown and a third, optional height. If using the Vertex and/or Vertex laser instruments to transfer heights to the Digitech caliper, the height value will always be stored under code=8. Up to 3 different heights per registration can be captured and stored, as total height, green crown height and the third, optional height.
“PC” is displayed again in the caliper display. If this operation is not successful, make sure that Ir has been selected in the SET menu in your Digitech caliper. If it still does not work, switch the serial port in the Settings menu, in DigiCom.
Digitech ENU rev. Feb 2011 NAME OF TREE SPECIES To change name of tree species, click ”Tree species” EDIT DATA Input data can be edited, changed, deleted or added in this menu. DELETE 0-DIAMETERS If certain 0-diameters that are not required have been input, they can be ignored and deleted here.
Digitech ENU rev. Feb 2011 EXPORT DATA In the following screen sequence, the chosen list to be exported and the way it should be presented in the out- file, are picked. 1. Choose list by marking the list-number under LIST.
Digitech ENU rev. Feb 2011 RESULT EXAMPLE STANDTABLE C:\test.txt 2002-02-13 07:34:33 LIST STAND TestStand 1 PART OF STAND part 2 TYPE OF INVENTORY PLOT INVENTORY Number of plots Number of trees Number of sample trees PLOT AREA m2 AREALFACTOR 32.5...
Digitech ENU rev. Feb 2011 EXAMPLE TAB SEPARATED EXCEL TXT FILE LIST STAND PARTOFSTAND PLOT PLOTAREAm2 SPECIE DIA mm HEIGTHdm HEIGTH2 HEIGTH3 1 1 TestStand 1 part 2 Pine 2 1 TestStand 1 part 2 Pine 3 1 TestStand 1 part 2...
Digitech ENU rev. Feb 2011 DATA FILE FROM THE CALIPER Data from the Digitech caliper can be stored as a dig-file. This file can be opened later on if you wish to delay export of data. A register in the dig-file will be stored as a four (4) digits string where the first digit signifies code as ´1`… ´8`and the three remaining digits show the tree diameter in mm.
Digitech ENU rev. Feb 2011 PRINT In this menu, data can be sent as a standtable to a HP-printer. MANTAX DIGITECH D * #1 #2 #3 #4 * #5 #6 #7 #8 TOT 0* 5 - - - * 1 - - - 6...
Digitech ENU rev. Feb 2011 The parameters are shown and can be changed as follows: Choose RAND menu and tree species 1 to 4 with the L or R key. Press E. The D value for the current tree species is now featured in the display.
Digitech ENU rev. Feb 2011 RADIO The Digitech has a built in radio transmitter, enabling wireless data transfer up to 25m/82feet with an external antenna, without antenna, up to5m/16feet. The antenna is mounted at the back of the Digitech caliper. Remove the cover before mounting the antenna.
Built-in loud speaker Tests IP67 moist + dust proof. See Declaration of conformity Digitech radio: UHF transceiver 433.92MHz ISM (Industrial, Scientific and Medical) frequency band, in compliance with the European Telecommunication Standard Institute specification EN 300 220-1 V1.2.1. Theoretical power output 10mW.
CE-marking Directive 93/68/EEGType of equipment Caliper. Brand name or trade mark Haglöf Sweden®, Digitech. Type designation(s)/Model no(s) Digitech & DigiRadio. Manufacturer’s name, address, telephone & fax no Haglöf Sweden AB, Klockargatan 8, SE- 882 21 Långsele, Sweden Tel: + 46 620-25585, Fax: + 46 620-20581 The following standards and/or technical specifications, which comply with good engineering practice in safety matters in force within the EEA, have been applied: Testreport/ technical construction file/ normative document.