Haglof DP II User Manual
Hide thumbs Also See for DP II:
Table of Contents

Advertisement

Doc:
Exhibit 8, User manual
Product:
Digitech Professional II
FCC ID:
2AAYWDPII

Advertisement

Table of Contents
loading

Summary of Contents for Haglof DP II

  • Page 1 Doc: Exhibit 8, User manual Product: Digitech Professional II FCC ID: 2AAYWDPII...
  • Page 2 User Guide The Digitech Professional II Version 1.0 Revised: 2014-01-14 © Haglöf Sweden 2014...
  • Page 3: Table Of Contents

    Example Multi Function Button................10 DP Radio Button ....................11 Changing the Battery ..................11 Synchronizing the DP Radio Enter Button ............11 Turn off/on the DP Radio Function..............11 Synchronization with the DP II Smart Scale ............12 Display......................12 Battery Indicator.....................12 Charging the Computer Terminal.................13 How to Charge....................14 PC Communication ....................15...
  • Page 4 Blue terminal ....................26 DP II Smart Scale ..................27 Unique jaw design .....................28 Robust Design....................28 Rechargeable Batteries - Environmental Concern...........29 Charging the DP II Smart Scale ................30 Foldable Jaws ....................31 How to adjust jaws angle .................32 Handle lock ....................32 Adjusting the Handle ..................33 Calibration......................33...
  • Page 5 European compliance statement ................37 Juridical information ..................38 Haglöf Sweden® ...................39...
  • Page 6: User Guide

    Revision: 2014-01-14 The Digitech Professional II (DP II) The DP II caliper incorporates the experience and know-how from Haglöf Sweden’s over 70 years of developing and manufacturing professional field measuring instrument solutions for use in forests all over the world.
  • Page 7: Digitech Professional Ii

    User Manual Revision: 2014-01-14 Digitech Professional II The Digitech Professional II system contains from the DP II Computer Terminal , the DP II Smart Scale and DP Radio Button. DP II Computer Terminal DP II Smart Scale and DP Radio Button...
  • Page 8 DP II Version 1.0/JN User Manual Revision: 2014-01-14 LCD Display Adjustment screw handle (2ea) IR receiver Handle Enter button Arrow buttons (4ea) Digitech Professional II, front view Jaws Holder Enter button Measuring scale, cm/mm/inch Digitech Professional II, upper view © Haglöf Sweden 2014...
  • Page 9 DP II Version 1.0/JN User Manual Revision: 2014-01-14 Serial port Holder Adjustment screw Loudspeaker jaw angle (2ea) USB interface and contact Digitech Professional II, side view for battery charge Enter button Digitech Professional II, backside view © Haglöf Sweden 2014...
  • Page 10 DP II Version 1.0/JN User Manual Revision: 2014-01-14 Battery charge contact Handle lock Digitech Professional II, backside viewfrom under © Haglöf Sweden 2014...
  • Page 11: System Description Dp Ii

    DP II Version 1.0/JN User Manual Revision: 2014-01-14 System Description DP II © Haglöf Sweden 2014...
  • Page 12: Computer Terminal

    User Manual Revision: 2014-01-14 Computer Terminal The DP II computer terminal includes the necessary interfaces to work with the system, such as the high visibility display, the 5 button keypad, the USB port, the serial port, loudspeaker, Bluetooth® and radio communication.
  • Page 13: Detachable Computer Terminal

    The DP II Smart Scale will in such cases look and work similar to a manual/mechanical caliper with its low weight and simple operation, but nevertheless carry all the advantages you would expect from a computer caliper.
  • Page 14: How To Assemble The Computer Terminal

    DP II Version 1.0/JN User Manual Revision: 2014-01-14 How to Assemble the Computer Terminal 1. Mount the support by attaching the two guide pins in the outlets on the upper part of the movable handle and fastening the locking screw firmly.
  • Page 15: The Buttons On The Keyboard

    DP II Version 1.0/JN User Manual Revision: 2014-01-14 The Buttons on the Keyboard The arrow buttons are used to navigate in the program and to enter data. By pressing two buttons at the same time, different functions can be activated, such as turn on backlit display, shut off computer terminal and more.
  • Page 16: Dp Radio Button

    DP II Version 1.0/JN User Manual Revision: 2014-01-14 DP Radio Button Changing the Battery The battery in the DP Radio button will last for approximately one year and depending on use. The DP Radio uses a CR2032 3V battery. To change the battery, follow these instructions: 1.
  • Page 17: Synchronization With The Dp Ii Smart Scale

    DP II Version 1.0/JN User Manual Revision: 2014-01-14 Synchronization with the DP II Smart Scale The computer terminal needs to be synchronized with the DP II Smart Scale measuring scale, to connect the radio units. Functions for connection available system menu.
  • Page 18: Charging The Computer Terminal

    In other cases the charging time can exceed 4 hours. USB mode will (in normal cases) automatically be active, provided that your terminal software allows it. Note that the DP II Smart Scale needs to be charged as well; see separate chapter on the DP II Smart Scale. Mini USB cable...
  • Page 19: How To Charge

    Place the opposite end (Type A) in a USB connection in your PC or in a USB charger. Connect the DP II USB adapter with the USB cable on the computer terminal. USB mode allows for quicker charging process. In normal cases the terminal software will automatically go to USB mode.
  • Page 20: Pc Communication

    1. Place a USB cable (Mini-B) to the DP II USB adapter. 2. Place the opposite end (Type A) in a USB connection in the PC. 3. Connect the DP II USB adapter with the USB cable on the terminal.
  • Page 21: Bluetooth

    DP II Version 1.0/JN User Manual Revision: 2014-01-14 BLUETOOTH® With Bluetooth technology you can work with wireless communication to the Internet or to other electronic instruments with Bluetooth. Energy consumption in comparably low. Bluetooth® is built-in the computer terminal for communication to external devices such as GPS, scanners and printers.
  • Page 22: Example: Send File To The Computer Terminal With Bluetooth

    DP II Version 1.0/JN User Manual Revision: 2014-01-14 Example: Send File to the Computer Terminal with Bluetooth® 1. The computer terminal: Reset the terminal by pressing all five (5) buttons simultaneously. 2. Select Bluetooth in the computer terminal as your Com Port.
  • Page 23: Program

    DP II. Updating programs If you have a valid license to a DP II program, this license is ”inherited” by the next program when upgrading, and uses the same product code. Delete older program versions after a new version has been started to reuse licenses.
  • Page 24: Activate The Program License

    Starting a new program A new program is started by selecting the menu ”Reset” (usually placed as a sub menu under “SETTINGS”). After a reset, the DP II will display a list of downloaded programs. Select one of the alternatives and press ENTER.
  • Page 25: Upgrading The Bios

    BIOS is the program that handles all hardware in the caliper. The BIOS needs to be upgraded on occasion as follows: 1. Reset the DP II by giving a short press on all five (5) buttons at the same time on the terminal. The DP II resets.
  • Page 26: Angle Measuring

    DP II Version 1.0/JN User Manual Revision: 2014-01-14 Angle Measuring The computer terminal contains an inclinometer that can be used to measure angles and to calculate heights. The Gator Eyes laser pointers accessories are recommended to use as aim. The Gator Eyes are factory...
  • Page 27: System Menus

    Select which application to delete. LICENSE A license key will be obtained from your Haglöf Sweden DP II distributor. If you do not have a license key, note the serial number SerNo and PROD before contacting your distributor. To activate the license, select menu SELECT PROGRAM and press ENTER.
  • Page 28: Delete Program

    DP II Version 1.0/JN User Manual Revision: 2014-01-14 Delete program To delete a program in the computer terminal select menu SELECT PROGRAM in the system menu and press ENTER. Use the up- or down button to select application and press ENTER. Select DELETE and press ENTER.
  • Page 29: Usb

    DP II Version 1.0/JN User Manual Revision: 2014-01-14 Activate the USB mode. In USB mode, the computer terminal is ready to be connected to PC via USB cable and to be handled as a USB memory stick. Files can be copied, deleted, created etc. with the regular file explorer in the PC.
  • Page 30: Settings

    User Manual Revision: 2014-01-14 Settings There are different settings that need to be considered in the system menu depending on software used in the DP II. Serial port Bluetooth® The Bluetooth is a built-in wireless communication port. Set as Master when the computer terminal is to initiate communication and connection to external devices.
  • Page 31: Test Menu

    Most menus under TEST MENU are used for service and error detection and not by DP II users. Scale Test for scale calibration and radio contact between the DP II Smart Scale and the computer terminal. Long timer 600 Test of the internal timer, 600ms.
  • Page 32: Dp Ii Smart Scale

    Revision: 2014-01-14 DP II Smart Scale The DP II Smart Scale is the DP II measuring scale and jaws. The DP II Smart Scale contains the measuring system, a battery and radio transmitter. The radio uses the ISM band on 2.4GHz. The DP II Smart Scale is synchronized with the computer terminal and can after synchronization exclusively send data to this specific terminal.
  • Page 33: Unique Jaw Design

    The DP II jaws are adjusted for smooth operation when measuring timber in piles and when working in narrow spaces. The firm jaw on the DP II Smart Scale has a special design that allows it to glide in between and under logs.
  • Page 34: Rechargeable Batteries - Environmental Concern

    DP II Smart Scale (excl. plastic details) Rechargeable Batteries - Environmental Concern Both the DP II Smart Scale measuring system and the computer terminal in the DP II uses rechargeable Li-ion batteries. Fully charged, the batteries will last for approximately one week depending on which application is used.
  • Page 35: Charging The Dp Ii Smart Scale

    Charging the DP II Smart Scale Connect the DP II USB adapter with the mini USB cable and USB charger, PC or USB car charger to the DP II Smart Scale according to the image. The charging time is approximately 3 hours.
  • Page 36: Foldable Jaws

    DP II Version 1.0/JN User Manual Revision: 2014-01-14 Foldable Jaws The measuring scale has foldable jaws that can be locked in position. To fold a jaw, push the lock up and fold the jaw according to the image below. Move the handle to the side as far as possible. Both jaws are locked in position and to each other along the scale.
  • Page 37: How To Adjust Jaws Angle

    Revision: 2014-01-14 How to adjust jaws angle The DP II Smart Scale angle of the jaws may need to be adjusted after some time of use. The right and left jaw are adjusted with a 2 mm Allen Key according to the image below.
  • Page 38: Adjusting The Handle

    Calibration The DP II Smart Scale will normally not need to be calibrated. Make it a habit, however, to check the displayed diameter to be identical to the scale featured diameter measure (or calibration guide). If there are divergences, (+-1mm) the DP II Smart Scale needs to be calibrated.
  • Page 39: Controlling The Dp Ii Smart Scale

    DP II Version 1.0/JN User Manual Revision: 2014-01-14 Controlling the DP II Smart Scale Controls of the Smart Scale is made in the application used, or in the menu SETTINGS/TESTS and Scale. Maintenance When cleaning the plastic housing, it is recommended to use a dry or lightly moist piece of cotton cloth to remove dust and dirt.
  • Page 40: Technical Specification

    Energy consumption >one week per charge depending on software • application. Measuring range standard: 500mm/18”; 600mm/24”; 800mm/30”; • 900mm/36”; 1000mm/40” Scale: DP II Smart Scale Aluminum, non reflecting, clear and durable • graduation Measuring system: Non incremental, sealed • Weight: 500mm - 890g/35.6oz, 600mm - 1000g/40oz, 800mm - •...
  • Page 41: Packet Contents

    Revision: 2014-01-14 Packet Contents The Digitech Professional packet will include different items as stated below. Length of the DP II Smart Scale is always stated at order (50cm, 65cm, 80cm, 95cm, 102cm, 18”, 24”, 30”, 36”) DP II computer caliper with Remote Radio Enter button...
  • Page 42: Product And Safety Specifications

    DP II Version 1.0/JN User Manual Revision: 2014-01-14 Product and Safety Specifications Regulatory compliance FCC statement The United States Federal Communications Commission (in CFR 47 Part 15.105) has specified that the following notice be brought to the attention of the users of...
  • Page 43 DP II Version 1.0/JN User Manual Revision: 2014-01-14 Juridical information Haglöf Sweden and its suppliers cannot warrant the performance or results when using the software or hardware, nor the documentation. No warranties or conditions are made; neither expressed nor implied, of merchantability, suitability or special fitness for any particular purpose.
  • Page 44 DP II Version 1.0/JN User Manual Revision: 2014-01-14 Haglöf Sweden® Haglöf Sweden® AB is a family company with long experience from developing and manufacturing professional forest measuring instrument solutions. Our genuine know-how in workshop production together with high-tech electronic assembling and advanced software development offer a unique concept, and the markets most complete product range for professional forest measuring work.