  • Page 1 English User Manual © Haglöf Sweden AB 2013/Rev. 201503...
  • Page 2 The Digitech Professional and DP II are market leading computer calipers used for forest inventory, log scaling, harvester calibration and more. Together with unique accessories, communication and compatibility with other instruments, the DP forms a complete measuring system for efficient field operations with versatility and focus on user adaptation and ruggedness.
  • Page 3: Table Of Contents

    Connection to PC BLUETOOTH® Example: Send File to the Computer Terminal with Bluetooth® Program Older programs Updating programs Transfer programs to the DP II Activate the program license Starting a new program Upgrading the BIOS © Haglöf Sweden AB 2013/Rev. 201503...
  • Page 4 System menus Rechargeable Batteries - Environmental Concern Delete all Charging the SmartScale LICENSE Foldable Jaws Delete program How to adjust jaws angle Files Handle lock File list Adjusting the Handle OPEN FILE Calibration Send Angle Measuring INFO Calibrating the inclinometer KERMIT Calibrate the zero angle (0) DELETE...
  • Page 5: Overview

    DP II Overview The DP II caliper incorporates the experience and knowledge gained from more than 70 years of developing and manu- facturing professional field measurement instrument solutions for use in forests all over the world. Haglöf Sweden’s exten- sive experience combined with innovation capacity and new ideas have resulted in this revolutionary computer caliper. The DP II includes these unique features and more: The lightest and most modern computer caliper on the market: approx.
  • Page 6 DP II Revised: 2015-03-16 15:47 DP II 1. DP II SmartScale 2. DP II computer terminal 3. Quick release attachment for the computer terminal 4. Adjustment screws for the handle 5. Loudspeaker 6. USB interface and contact for battery charge 7.
  • Page 7: Dp Ii Computer Terminal

    Version: 1.2 User Manual Revised: 2015-03-16 15:47 DP II DP II Computer Terminal 1. LCD Display 2. IR receiver 3. Enter button 4. Arrow buttons (4ea) 5. Serial Port 6. Loudspeaker 7. USB interface and contact for battery charge © Haglöf Sweden AB 2013/Rev.201503|...
  • Page 8: Smartscale

    User Manual Version: 1.2 DP II Revised: 2015-03-16 15:47 SmartScale 1. Foldable jaws 2. Lock for the foldable jaws 3. Assembly point for quick release attachment for the computer terminal 4. Enter button 5. LED Indicator 6. Scale 7. Movable handle 8.
  • Page 9: System Description

    II computer terminal is both a stand-alone device and can be assembled and used with the moveable handle. In this mode, the DP II will look like and work similar to a tradi- tional computer caliper. The DP II Computer Terminal can be detached from the movable handle and the SmartScale.
  • Page 10: The Buttons On The Keyboard

    DP II Revised: 2015-03-16 15:47 The Buttons on the Keyboard When the DP II computer terminal is mounted on the handle, many users prefer to work with the ”trigger-style” Enter button(1) on the handle. When the computer terminal is used as a stand-alone computer, the onboard Enter button(2) on the terminal is preferred.
  • Page 11: Operating Procedure

    2 The computer terminal can be used as a stand-alone hand- held computer and attached onto the DP II Wrist holder accessory and worn on your wrist. 1. Steer the guide pins in the metal holder into the out- lets on the upper part of the computer terminal.
  • Page 12: Dp Radio Button

    2. Press 5-6 times on the DP Radio Button to drain it The Radio Enter button is fac- completely. tory assembled on the DP II caliper. 3. Assemble the battery with – to the inside and + to the battery lid.
  • Page 13: Synchronization With The Smartscale

    Charging the Computer Terminal The computer terminal needs to be synchronized with the The DP II SmartScale and the DP II terminal use re- SmartScale measuring scale, to connect the radio units. chargeable Li-ion batteries. Fully charged batteries last for Functions for connection are available in the system menu.
  • Page 14: Pc Communication

    The data files are usually located in the directory \\DATA, and programs for the caliper in the directory \\PRG. 7. Finish the session by pressing Escape in the DP II computer terminal. 8. Remove the USB adapter by releasing the stop and pull the USB adapter backwards.
  • Page 15: Example: Send File To The Computer Terminal With Bluetooth

    Example: Send File to the Computer Terminal with Blue- Transfer programs to the DP II 1. Reset the DP II by giving a short press on all five (5) tooth® buttons on the terminal at the same time. The DP II 1.
  • Page 16: Starting A New Program

    Use the ”Delete all” if you wish to delete all downloaded 1. Reset the DP II by giving a short press on all five (5) applications. Individual applications can be deleted through buttons at the same time on the terminal. The DP II menu SELECT PROGRAM.
  • Page 17 There are different settings that need to be considered in be selected and handled in the following menu system. the system menu depending on software used in the DP II. The selection ”Delete all” deletes all data files in the direc- Serial port tory ”\DATA”.
  • Page 18 Control and calibration of the DP DME accessory. measuring timber in piles and when working in narrow spaces. The firm jaw on the DP II Smart Scale has a special Long timer 600 design that allows it to slide in between and under logs Test of the internal timer, 600ms.
  • Page 19 USB cable that can be connected to a PC or to an external USB charger. Charging the SmartScale Connect the DP II USB adapter with the mini USB cable and USB charger, PC or USB car charger to the Smart- Scale according to the image. The charging time is approxi- mately 3 hours.
  • Page 20 User Manual Version: 1.2 DP II Revised: 2015-03-16 15:47 Handle lock Calibration The movable handle on the scale can be locked if moved The SmartScale will normally not need calibration. Make toward the the fixed jaw. This is practical when carrying the it a habit to check the displayed diameter to be identical to caliper in the handle and in other transport situations.
  • Page 21 Version: 1.2 User Manual Revised: 2015-03-16 15:47 DP II Calibrating the inclinometer The clinometer is calibrated on delivery but may need fine adjustment according to below procedure: 1. Go to ”SYSTEM MENU—SETTINGS—ANGLE— CAL XYZ” 2. Place the computer terminal on a flat surface (a table) with the display facing up.
  • Page 22 DP DME The Digitech® Tape is an electronic measuring tape for lengths The DP DME accessory to the DP II caliper can quickly up to 7.5m/yds. The Digitech Tape is assembled on the compu- and accurately deliver information on distance from the ter terminal.
  • Page 23 Version: 1.2 User Manual Revised: 2015-03-16 15:47 DP II Technical Specification Data terminal Memory capacity: 1GB Flash File System. Non-volatile, high data security ♦ 1Mb high-speed RAM ♦ Processor: Low Power 32 bit Arm Based Processor Display: Graphical black-white, 128x64 pixles graphic interface...
  • Page 24 Packet Contents Depending on selected configuration, the DP II packet will include different items as stated below. Length of the SmartScale is always stated at order (50cm, 60cm, 65cm, 80cm, 95cm, 100cm, 102cm, 18”, 24”, 30”, 36”)
  • Page 25 Version: 1.2 User Manual Revised: 2015-03-16 15:47 DP II © Haglöf Sweden AB 2013/Rev. 201503 |...
  • Page 26 User Manual Version: 1.2 DP II Revised: 2015-03-16 15:47 Juridical information Haglöf Sweden and its suppliers cannot warrant the performance or results when using the software or hardware, nor the documentation. No warranties or conditions are made; neither expressed nor imp- lied, of merchantability, suitability or special fitness for any particular purpose.
  • Page 27 Version: 1.2 User Manual Revised: 2015-03-16 15:47 DP II © Haglöf Sweden AB 2013/Rev. 201503 |...
  • Page 28 Haglöf Sweden AB ¤ Klockargatan 8 SE-882 30 Långsele ¤ Ph +46 620 255 80, Fax +46 620 205 81 ¤ www.haglofsweden.com © Haglöf Sweden AB 2013/Rev. 201503...