Section I - Pre-Installation Items; Code Compliance; Determining Product Location; Boiler Replacement - Prestige Solo 110 Installation And Maintenance Manual

Table of Contents

Advertisement

Pre-Installation Items

SECTION I - Pre-Installation Items

Code Compliance

This product must be installed in accordance to
the following:
-
All applicable local, state, national and
provincial codes, ordinances, regula-
tions and laws.
-
For installations in Massachusetts -
code requires the boiler to be installed
by a licensed plumber or gas fitter, and
if antifreeze is utilized, the installation
of a reduced pressure backflow preven-
ter device is required in the boiler's cold
water fill or make up water supply line.
-
For installation in Massachusetts
All direct vented appliances must com-
ply with the guidelines as outlined on
page 11.
-
The National Fuel Gas Code NFPA54/
ANSI Z 223.1 - Latest edition.
-
National Electric Code ANSI/NFPA 70.
-
For installations in Canada -"Installation
Code for Gas Burning Equipment"
CGA/B149.1 or B149.2 Canadian
Electrical Code Part 1 CSA C 2 2 . 1 .
-
Standards for Controls and Safety
Devices for Automatically Fired Boilers,
ANSI/ASME CSD-1, when required.
NOTICE
The PRESTIGE boiler gas manifold and
gas controls meet the safe lighting and
o t h e r performance re q u i rements as
specified in ANSI Z21.13 latest edition.

Determining Product Location

Before locating the PRESTIGE check for con-
venient locations to:
-
Heating system piping
-
Venting
-
Gas supply piping
-
Electrical service
Ensure the boiler location allows the combus-
tion air/vent piping to be routed directly through
the building and terminate properly outside with
a minimum amount of length and bends.
Ensure the area chosen for the installation of the
PRESTIGE is free of any combustible materi-
als, gasoline and other flammable liquids.
WARNING
Failure to remove or maintain the area
free of combustible materials, gasoline
and other flammable liquids or vapors
can result in severe personal injury,
death or substantial property damage.
Ensure the PRESTIGE and its controls are
protected from dripping or spraying water dur-
ing normal operation or service.
The PRESTIGE should be installed in a loca-
tion so that any water leaking from the boiler or
piping connections or relief valve will not
cause damage to the area surrounding the unit
or any lower floors in the structure.

Boiler Replacement

If the PRESTIGE is replacing an existing boil-
er, the following items should be checked and
corrected prior to installation:
-
Boiler piping leaks and corrosion.
-
Improper location and sizing of the
expansion tank on the boiler heating
loop.
-
If applicable, level and quality of freeze
protection within the boiler system.
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solo110

Table of Contents